Briggs & Stratton — B. No- Return to step 8 (under Test 1: Check Battery Voltage Supply).
For these Briggs & Stratton models: 10 kW, 8 kW.
Browse Briggs & Stratton generators & specs →
Procedure
- 26. See Figure A14. Disconnect control wire (Wire 98 on some models) from spade contact at starter
- 27. Install 15 Amp fuse in control panel.
- 28. Press and hold MANUAL on control panel to crank engine.
- 29. Is DC voltage on control wire at starter solenoid equal to or greater than 9.6 VDC?
- A. Yes- Install new starter. Retest.
- B. No- Repair or replace wiring between starter relay and starter solenoid. Retest.
Source: manual:Briggs_Air-CooledRepairManual80019677.pdf. Figures and steps are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.