Home›Repair guides›Basler›Relabel the RDP-110 Programmable Alarm and Pre-Alarm LEDs

Basler — Relabel the RDP-110 Programmable Alarm and Pre-Alarm LEDs

Maintenance · Programmable alarm/pre-alarm label cards

From a Basler service manual — check it applies to your exact model before use.

Before you start

  • Remove all control power from the RDP-110 before opening the front panel.
  • When handling the front panel, avoid touching the circuit board.

Procedure

  1. Print the label text on readily-available address label sheets. The label cards accommodate adhesive-backed labels measuring 0.5 by 1.75 inches. Avery part number 18167 is suitable.
  2. Remove all control power from the RDP-110.
  3. Remove the four Phillips screws from the front panel and separate the front panel from the conduit box.
  4. Disconnect the two connectors attached to the circuit board mounted to the front panel. Avoid touching the circuit board.
  5. Lay the front panel face-down on a suitable work surface.
  6. Grasp the tab of the label card to be changed and pull free.
  7. Apply the labels created in step 1 to the label cards, using the rectangle outlines as guides.
  8. Insert each label card into the appropriate panel slot, oriented properly by viewing the custom labels through the front panel label windows.
  9. Move the panel assembly adjacent to the conduit box and reconnect the cables to the two circuit board connectors.
  10. Secure the front panel to the conduit box with the four Phillips screws. Maximum torque is 17 inch-pounds or 2 newton meters.
  11. If desired, verify the function of the reprogrammed indicators before returning the RDP-110 to service.

Tools required

  • Phillips screwdriver Amazon
  • Adhesive-backed address labels (Avery part number 18167 or equivalent) Amazon

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • Front panel screw maximum torque: 17 inch-pounds or 2 newton meters

Source: Basler service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.

More Basler repair guides →