Basler — Functional Test Procedure
Testing & diagnosis · RDP-110 Remote Display Panel
From a Basler service manual — check it applies to your exact model before use.
Before you start
- To avoid personal injury or equipment damage, only qualified personnel should perform the procedures in this manual.
Procedure
- Connect the test setup as shown in Figure 5-1.
- Apply dc power.
- The Display Panel On LED should turn on.
- Press and hold the Lamp Test pushbutton.
- The alarm should sound and all LEDs should turn on.
- Release the pushbutton; the alarm and LEDs should turn off.
- Apply the 10 hertz signal.
- Press and release the Lamp Test pushbutton.
- Each LED and the horn should annunciate in sequence before repeating.
- Press and release the Alarm Silence pushbutton.
- The cycling indicators should stop when the Alarm Silence pushbutton is pressed.
- Remove the 10 Hz source and the DC power input.
- Repeat the above test procedure with AC power applied instead of the DC power.
Tools required
- DC power supply, 24 volts Amazon
- 2 each, one ampere fuses Amazon
- Voltage source, 50/60 hertz, 100/120 volts Amazon
- Signal generator, 10.0 hertz, 5 volts peak to peak, square wave
Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.
Source: Basler service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.