Basler — Adjust Voltage Stability R4

Adjustments · Stability adjustment R4

From a Basler service manual — check it applies to your exact model before use.

Procedure

  1. Loosen the locking nut on R4.
  2. Rotate R4 clockwise (CW) approximately 30° beyond the point that stable operation is obtained.
  3. Tighten lock nut on R4.

Specs & values

  • Factory set in 75% rotation (CW) position

Source: Basler service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.