Aurora — Glow Plug Setting Adjustment
For these Aurora models: DynaGenTM ES52, ES52.
Browse Aurora generators & specs →
Procedure
- Remove the wires connected to the Timer terminal # 12 and the Crank terminal # 5.
- Apply power to the Start/Stop terminal # 10.
- Measure the time that the "Timer" LED remains ON.
- Remove power from the Start/Stop terminal # 10.
- Increase or decrease pot setting as required. The pot resolution is 1.6 seconds/turn.
- Return to step 2 as needed.
- Re-connect the wires to the Timer terminal # 12 and the Crank terminal # 5.
Specs & torque values
- Pot resolution: 1.6 seconds/turn
- Adjustable range: 0-32 seconds
Source: manual:dynagen-es52-user-manual-en.pdf. Figures and steps are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.