Before you start

  • High voltages are present in and around transfer switch equipment. Before inspecting or maintaining this equipment, disconnect the line power by opening and locking out, if possible, the next highest disconnect device.

Procedure

  1. Make the transfer switch equipment safe for inspection and/or maintenance.
  2. Inspect the structure area for safety hazards or potential maintenance problems.
  3. Inspect the contactor for dust, dirt, soot, grease, moisture, or corrosion.
  4. Check for material integrity, uneven wear, discoloration, or loose hardware.
  5. Check the terminals and connectors for looseness or signs of overheating.
  6. Exercise the contactor if it is not often exercised while in operation.
  7. Return the transfer switch equipment to service.