Home›Repair guides›Aurora Generators›Selecting a Timer Function

Aurora Generators ES52 — Selecting a Timer Function

Adjustments · DIP switches 7 and 8

For the Aurora Generators ES52, from the Aurora Generators service manual.

Browse Aurora Generators generators & specs →

Procedure

  1. Set DIP switches 7 and 8 per table.
  2. Glow Plug: OFF/OFF, adjustable 0 - 32 seconds.
  3. Air-gate: ON/OFF, fixed at 10 seconds.
  4. Choke: OFF/ON, not adjustable.
  5. Slow: ON/ON, adjustable 0 - 256 seconds.
  6. Timer output is terminal #12.

Specs & values

  • Glow Plug 0 - 32 seconds
  • Air-gate fixed 10 seconds
  • Choke not adjustable
  • Slow 0 - 256 seconds

Source: Aurora Generators service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.

More Aurora Generators repair guides →