Aurora Generators ES52 — Selecting a Timer Function
Adjustments · DIP switches 7 and 8
For the Aurora Generators ES52, from the Aurora Generators service manual.
Browse Aurora Generators generators & specs →
Procedure
- Set DIP switches 7 and 8 per table.
- Glow Plug: OFF/OFF, adjustable 0 - 32 seconds.
- Air-gate: ON/OFF, fixed at 10 seconds.
- Choke: OFF/ON, not adjustable.
- Slow: ON/ON, adjustable 0 - 256 seconds.
- Timer output is terminal #12.
Specs & values
- Glow Plug 0 - 32 seconds
- Air-gate fixed 10 seconds
- Choke not adjustable
- Slow 0 - 256 seconds
Source: Aurora Generators service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.