Aurora Generators ES52 — Crank Disconnect and Over-Speed Pot Adjustment
Adjustments · Crank Disconnect pot, Over-Speed pot
For the Aurora Generators ES52, from the Aurora Generators service manual.
Browse Aurora Generators generators & specs →
Procedure
- Factory Crank Disconnect: 20 Hz low-speed mode, 300 Hz high-speed mode.
- One turn gives approximately 6.4 Hz low speed and 205 Hz high speed.
- Factory Over-speed: 69 Hz low-speed mode, 1080 Hz high-speed mode.
- One turn gives approximately 13 Hz low speed and 410 Hz high speed.
- Best method is to use a signal generator to determine proper setpoints.
- If no signal generator, adjust pots using factory defaults and Hz/turn values.
Tools required
- signal generator (function generator) Amazon
Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.
Specs & values
- Crank Disconnect 20 Hz low / 300 Hz high
- Crank Disconnect turn ≈ 6.4 Hz low / 205 Hz high
- Over-speed 69 Hz low / 1080 Hz high
- Over-speed turn ≈ 13 Hz low / 410 Hz high
Source: Aurora Generators service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.