Aurora Generators ES52 — Adjusting Timer Duration
Adjustments · Timer pot, terminals 12 and 5, Start/Stop terminal 10
For the Aurora Generators ES52, from the Aurora Generators service manual.
Browse Aurora Generators generators & specs →
Procedure
- Glow Plug setting (DIP switches 7 and 8 OFF): remove wires from Timer terminal #12 and Crank terminal #5.
- Apply power to Start/Stop terminal #10.
- Measure time Timer LED remains ON.
- Remove power from Start/Stop terminal #10.
- Increase or decrease pot setting as required; pot resolution is 1.6 seconds/turn.
- Return to step 2 as needed.
- Reconnect wires to Timer terminal #12 and Crank terminal #5.
- Slow setting (DIP switches 7 and 8 ON): apply power to Start/Stop terminal #10.
- Allow engine to crank and start; Engine Running LED turns ON.
- Timer LED illuminates; measure time LED remains ON.
- Adjust pot as required; pot resolution is 12.8 seconds/turn.
- Return to step 1 as needed.
Specs & values
- Glow Plug pot resolution 1.6 seconds/turn
- Slow pot resolution 12.8 seconds/turn
Source: Aurora Generators service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.