Atlas Copco — Replacing the coolant
Maintenance · Cooling system
From a Atlas Copco owner's manual covering: QAX 12 Dd, QAX 20 Dd, QAX 30 Dd, Qc1002. Check it applies to your exact model before use.
Applies to: Deutz F2M 2011 F engine, Deutz F3M 2011 F engine, Deutz BF3M 2011 F engine
Before you start
- Never remove the cooling system filler cap while coolant is hot
- Never mix different coolants
- Topping up with water only is not allowed
Procedure
- Drain the entire cooling system completely.
- Dispose or recycle used coolant per local laws.
- Flush twice with clean water.
- Determine amount of PARCOOL EG required and pour into the radiator top tank.
- Run the engine until normal operating temperature is reached, then stop and cool.
- Recheck coolant level and add if necessary.
Specs & values
- Cooling system capacity 8 l
- PARCOOL EG premixed 50/50
Source: Atlas Copco owner's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.