Home›Repair guides›Atlas Copco›Erection of the lighting tower

Atlas Copco — Erection of the lighting tower

Operation · Lighting tower option

From a Atlas Copco owner's manual covering: QAX 12 Dd, QAX 20 Dd, QAX 30 Dd, Qc1002. Check it applies to your exact model before use.

Applies to: Deutz F2M 2011 F engine, Deutz F3M 2011 F engine, Deutz BF3M 2011 F engine

Before you start

  • The lighting tower should never be left unattended
  • Before moving the unit, ALWAYS lower the mast and secure it on the transport frame
  • When the genset is mounted on a lighting tower it is NOT permitted to use the lifting eye

Procedure

  1. Position the generator: rear-end upwind, immobilize with handbrake or chocks, level with jockey wheel.
  2. Extend the four stabilizers as far as possible and lock with levers HLS.
  3. Unlock and lower the stabilizer feet; lock in a foreseen hole.
  4. Wind down the foot until it touches the ground and clamps the stabilizer firmly.
  5. Loosen the elevation cable by turning the winding mechanism lever clockwise.
  6. Unlock the mast by raising lever LTF at the back of the transport frame.
  7. Raise the mast from horizontal to vertical; check the locking pin secures the vertical position.
  8. Raise the mast to the desired height by turning the winding mechanism lever.

Specs & values

  • Maximum allowable slope of terrain 15°
  • Mast can be turned to locked positions at 45°, 90°, 135° and 180°

Source: Atlas Copco owner's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.