Home›Repair guides›Atlas Copco›Belt exchange/tensioning

Atlas Copco — Belt exchange/tensioning

Maintenance · V-belt(s)

From a Atlas Copco owner's manual covering: SF 1, SF 11, SF 15, SF 2, SF 4, SF 6, SF 8. Check it applies to your exact model before use.

Browse Atlas Copco generators & specs →

Before you start

  • In case of two belts, the belts must be replaced as a set, even if only one seems worn. Use Atlas Copco belts only.

Procedure

  1. Loosen motor hold-down bolts (3).
  2. Loosen the belt tension by screwing bolts (4) equally and take out the belts.
  3. Install new belts in the grooves of the pulleys.
  4. Tension the belts by screwing bolts (4) equally. Make sure the pulleys remain aligned.
  5. Tighten bolts (3).
  6. Check the belt tension after the first 500 running hours.

Specs & values

  • Tension is correct if deflection is between 5 mm and 7 mm when exerting a force of 25 N on the belt midway between the pulleys
  • Maximum parallel out-of-line: 0.5 mm
  • Maximum angular out-of-line: 0.5 degrees

Source: Atlas Copco owner's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.