Home›Repair guides›Atlas Copco›Activating a dry-charged battery

Atlas Copco — Activating a dry-charged battery

Maintenance

From a Atlas Copco owner's manual covering: QAX 12 Dd, QAX 20 Dd, QAX 30 Dd, Qc1002. Check it applies to your exact model before use.

Applies to: Deutz F2M 2011 F engine, Deutz F3M 2011 F engine, Deutz BF3M 2011 F engine

Before you start

  • Before handling batteries, read the relevant safety precautions

Procedure

  1. Take out the battery.
  2. Battery and electrolyte must be at equal temperature above 10°C.
  3. Remove cover and/or plug from each cell.
  4. Fill each cell with electrolyte until level reaches 10 to 15 mm above plates.
  5. Rock the battery a few times so air bubbles escape; wait 10 minutes and recheck.
  6. Refit plugs and/or cover.
  7. Place the battery in the generator.

Tools required

  • Electrolyte (sulphuric acid solution in distilled water) Amazon

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • Electrolyte level 10 to 15 mm above the plates
  • Battery and electrolyte above 10°C

Source: Atlas Copco owner's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.