Home›Repair guides›Allmand›Replacing Section Seals

Allmand — Replacing Section Seals

Repair & overhaul · Gresen V-10 control valve

From a Allmand operator's manual — check it applies to your exact model before use.

Before you start

  • Use care when sliding work sections on tie rods to avoid dislodging O-rings.

Procedure

  1. Disassemble valve as described in previous section.
  2. Remove old O-ring section seals; do not scratch sealing surface areas.
  3. Thoroughly clean O-ring counter bores and surfaces of each valve section.
  4. Place valve assembly on a flat surface for reassembly.
  5. Replace four O-ring seals; seal kit contains seals for one work section/inlet cover.
  6. Replace work sections on assembly studs in reverse order of removal.
  7. O-ring counter bores with O-rings should be to your right (downstream side).
  8. Replace lock washers and nuts; torque stud nuts evenly to 15 ft. lbs.

Specs & values

  • Stud nuts torque: 15 ft. lbs.

Source: Allmand operator's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.

More Allmand repair guides →