Home›Repair guides›Allmand›Manual DPF Regeneration

Allmand — Manual DPF Regeneration

Operation · Diesel particulate filter (DPF)

From a Allmand service manual — check it applies to your exact model before use.

Before you start

  • When DPF regeneration required lamp goes on, take immediate specified action.
  • Do not stop engine during enforced regeneration operation, except for unavoidable conditions.

Procedure

  1. Regeneration required lamp and error lamp go on; regeneration lamp flashes and engine speed changes to 1,350 min-1.
  2. Close service valve.
  3. Keep pressing regeneration switch longer than 3 seconds.
  4. Regeneration required lamp lights off and cleaning exhaust filter lamp goes on; regeneration lamp changes to lighting.
  5. Engine speed gradually increases up to approximately 2,200 min-1.
  6. Manual regeneration operation is performed about 30 minutes.
  7. All lamps go off and it returns to normal engine speed.

Specs & values

  • Manual regeneration time: about 30 minutes
  • Engine speed during regeneration: approximately 2,200 min-1

Source: Allmand service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.