Home›Repair guides›Allmand›Change of Pellet Assembly of By-pass Valve

Allmand — Change of Pellet Assembly of By-pass Valve

Repair & overhaul

From a Allmand service manual — check it applies to your exact model before use.

Procedure

  1. Stop the unit and make sure no residual pressure is left in the separator receiver tank.
  2. Confirm compressor oil temperature is amply low, open drain valves to empty oil completely.
  3. Remove bolt 1, then the pellet assembly 2 and O-ring 3.
  4. Replace pellet assembly and O-ring with new ones; install O-ring coated thinly with compressor oil.
  5. Supply compressor oil through the filler port on the receiver tank.
  6. Start operation and check the function of by-pass valve.

Specs & values

  • By-pass valve actuating temperature: 180±37°F (82±3℃)
  • By-pass valve fully closing temperature: 192±36°F (89±2℃)

Source: Allmand service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.

More Allmand repair guides →