Procedure

  1. Check valve hot wire.
  2. Check valve ground wire.
  3. Check switch controlling the valves.
  4. Check for low voltage.
  5. Check solenoid coil.
  6. Check for dirt in valve cartridge: energize valve without starting motor and listen for valve shift.
  7. If not heard, remove cartridge and blow compressed air through all parts to dislodge dirt.
  8. Clean all parts in solvent, blow dry, and lubricate.

Source: Allmand service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.