Testing & diagnosis · 2-way/2-position normally closed valve

From a Allmand service manual covering: M-250 Series, M-258, M-259, M-301, M-303, M-304, M-310, M-311, M-313, M-314, M-319, M-326…. Check it applies to your exact model before use.

Procedure

  1. Check valve hot wire.
  2. Check valve ground wire.
  3. Check switch controlling the valve.
  4. Check for low voltage.
  5. Check solenoid coil.
  6. Check for dirt in valve cartridge: energize valve without starting motor and listen for click.
  7. If no shift, remove cartridge from valve body and blow compressed air through cartridge in both directions while holding plunger off seat.
  8. Check for bent valve stem; replace valve.

Source: Allmand service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.

More Allmand repair guides →