Home›Repair guides›Allis-Chalmers›Valve Lash Adjustment

Allis-Chalmers — Valve Lash Adjustment

Adjustments · Valve rocker arms and valves

From a Allis-Chalmers owner's manual covering: 11000, 11000 MKIT, 11000MKII, T1Q00GMKII. Check it applies to your exact model before use.

Applies to: Allis-Chalmers 11000 / 11000MKII engine

Before you start

  • Ensure adjusting screws are turned upward enough after mechanical work so pistons cannot strike valves when cranking.

Procedure

  1. Operate engine to minimum 160 F (344 K) coolant temperature, then stop engine.
  2. Clean valve rocker covers and surrounding area.
  3. Remove breather tube upper section, rocker cover nuts, sealing washers and covers.
  4. Crank engine until No. 6 exhaust valve is almost closed and intake valve starts to open.
  5. Check and adjust intake and exhaust valve lash for No. 1 cylinder to 0.018 in.
  6. Loosen locknut; turn adjusting screw clockwise to decrease or counterclockwise to increase clearance; tighten locknut.
  7. Following firing order 1-5-3-6-2-4, position each cylinder in turn and adjust its valves (5, 3, 6, 2, 4).
  8. Recheck lash after tightening each locknut.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • 0.018 in (0.46 mm) hot, intake and exhaust
  • 0.020 in (0.51 mm) cold setting

Full service-parts list: Allis-Chalmers 11000 / 11000MKII engine →

Source: Allis-Chalmers owner's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.