Home›Repair guides›Allis-Chalmers›Replacing Air Cleaner Cartridge (Tube Type)

Allis-Chalmers — Replacing Air Cleaner Cartridge (Tube Type)

Maintenance

From a Allis-Chalmers operator's manual covering: 6138, 685, SERIES 6138, SERIES 670. Check it applies to your exact model before use.

Before you start

  • Do not clean dirty element
  • Do not pound center of cartridge

Procedure

  1. Loosen clamp fasteners in housing, remove vertical air inlet adaptor and rain cap if applicable
  2. Remove moisture separator or pre-cleaner depending on unit
  3. Insert fingers into cartridge openings and loosen all four corners, one at a time, by pulling straight out; after breaking seal remove cartridge
  4. Remove all foreign matter from inside total air cleaner unit and dust discharge valve
  5. Inspect new cartridge for shipping damage prior to installation
  6. Install new cartridge into housing; firmly press all edges and corners against sealing flange to effect positive seal
  7. Tighten fasteners finger tight then turn 1.5 turns with tool in sequence
  8. Make certain all connections are tight; reset service indicator

Specs & values

  • Turn fastener 1.5 turns with tool

Source: Allis-Chalmers operator's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.