Home›Repair guides›Allis-Chalmers›Draining cooling system

Allis-Chalmers — Draining cooling system

Maintenance

From a Allis-Chalmers operator's manual covering: 16000MKII, 17000MKII, 21000MKII, 25000MKII. Check it applies to your exact model before use.

Before you start

  • If engine has immersion heater, disconnect power source.

Procedure

  1. Disconnect power source from immersion heater thermostat.
  2. Make certain engine is level for complete draining.
  3. Remove radiator or expansion tank cap.
  4. Open vent cock in top of thermostat housing.
  5. Open drain cocks at each end of intercooler and intake manifold assembly if applicable.
  6. Open drain cock at forward right side of cylinder block.
  7. Open drain cock at water pump inlet.
  8. Open radiator drain cock and remove coolant filter or drain plug.

Source: Allis-Chalmers operator's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.

More Allis-Chalmers repair guides →