Home›Repair guides›Allis-Chalmers›Air Cleaner Cartridge Replacement and Service

Allis-Chalmers — Air Cleaner Cartridge Replacement and Service

Maintenance

From a Allis-Chalmers owner's manual covering: 11000, 11000 MKIT, 11000MKII, T1Q00GMKII. Check it applies to your exact model before use.

Applies to: Allis-Chalmers 11000 / 11000MKII engine

Before you start

  • Do not clean or reuse a dirty cartridge. Do not cover the precleaner face.

Parts for this job

  • 30396811 Air filter buy

Part numbers from the service-parts list for Allis-Chalmers 11000 / 11000MKII engine. Verify against your serial number before ordering; some links are affiliate links.

Procedure

  1. Loosen wing/nuts and clamps; remove moisture eliminator or precleaner after removing its flexible hose.
  2. Loosen all four cartridge corners by pulling straight out; remove and discard cartridge.
  3. Inspect dirty cartridge for soot or oil to detect exhaust leaks or breather fumes.
  4. Remove all foreign material from inside the housing.
  5. Install new cartridge; press all edges and corners firmly against the sealing flange.
  6. Clean moisture eliminator or precleaner if necessary.
  7. Install moisture eliminator (drain holes down) or precleaner (dust bin down).
  8. Tighten clamp fasteners in diagonal sequence (hex nut type to 72 lb-in).
  9. Install flexible hose over precleaner elbow and tighten clamp.
  10. Reset service indicator by pressing reset button.

Specs & values

  • Hex nut clamp type 72 lb-in (8 Nm)
  • Wingnut type: finger tight plus 1-1/2 to 2 turns

Full service-parts list: Allis-Chalmers 11000 / 11000MKII engine →

Source: Allis-Chalmers owner's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.

More Allis-Chalmers repair guides →