Home›Repair guides›Allis-Chalmers›Air cleaner cartridge replacement

Allis-Chalmers — Air cleaner cartridge replacement

Maintenance

From a Allis-Chalmers operator's manual covering: 16000MKII, 17000MKII, 21000MKII, 25000MKII. Check it applies to your exact model before use.

Before you start

  • Do not clean or reuse dirty cartridge. Do not pound in center of cartridge.

Procedure

  1. Loosen wing/nuts and clamps; remove moisture eliminator or precleaner.
  2. Insert fingers into cartridge openings and loosen all four corners by pulling straight out.
  3. Remove cartridge by pulling straight out and slightly up; discard dirty cartridge.
  4. Inspect inside of housing and remove all foreign material.
  5. Install new cartridge; press all edges and corners against sealing flange.
  6. Clean moisture eliminator or precleaner if necessary.
  7. Install moisture eliminator with drain holes to bottom or precleaner with dust bin to bottom.
  8. Tighten clamp fasteners in diagonal sequence and reset service indicator.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • Hex nut type clamp 72 lb-in (8 Nm)
  • Wingnut type finger tight plus 1-1/2 to 2 turns

Source: Allis-Chalmers operator's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.