Home›Repair guides›Allis-Chalmers›Filling the Cooling System

Allis-Chalmers 3500 MK II / SOOMKII 1.5 — Filling the Cooling System

Maintenance

For the Allis-Chalmers 3500 MK II / SOOMKII 1.5, from the Allis-Chalmers owner's manual.

Applies to: Allis-Chalmers 3500 MKII engine

Before you start

  • Do not use antifreeze solutions harmful to aluminum.
  • Do not remove pressure cap while coolant temperature is 212 F (373 K) or above.

Procedure

  1. Close all drains opened to drain the system.
  2. Fill system with clean soft water or antifreeze solution to about 1.50 in below bottom of filler neck.
  3. Install filler cap.
  4. For heat exchanger type, close vent cocks when coolant free of air bubbles appears.
  5. Operate engine at normal operating temperature to vent all air.
  6. Check coolant level and add coolant to attain proper level.

Specs & values

  • Fill level approximately 1.50 in (38.10 mm) below bottom of filler neck

Full service-parts list: Allis-Chalmers 3500 MKII engine →

Source: Allis-Chalmers owner's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.