Home›Repair guides›Allis-Chalmers›Fan, Fan Spacer, and Fan Pulley Inspection and Installation

Allis-Chalmers 2900 Mark II — Fan, Fan Spacer, and Fan Pulley Inspection and Installation

Maintenance · Fan, fan spacer, fan pulley

For the Allis-Chalmers 2900 Mark II, from the Allis-Chalmers service manual.

Procedure

  1. Remove fan guard; loosen capscrews and push alternator in to relieve tension on fan belts.
  2. Remove capscrews and lock washers securing fan and fan spacer to pulley hub; remove fan and fan spacer.
  3. Slip fan belts off pulley and remove pulley.
  4. Inspect fan for cracks, loose rivets, or bent blades. Repair or replace if necessary.
  5. Inspect fan spacer and pulley for wear or damage. Replace if necessary.
  6. Position pulley on hub; position belts in pulley grooves.
  7. Install fan spacer and fan, securing with capscrews and lockwashers. Tighten capscrews to a torque of 30 to 35 lbs.ft. (4,14-4,83 kg/m).
  8. Adjust the fan belts; refer to 2.3.2.

Specs & values

  • Fan capscrews torque: 30 to 35 lbs.ft. (4,14-4,83 kg/m)

Source: Allis-Chalmers service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.

More Allis-Chalmers repair guides →