Specifications
| Fuel | Diesel |
|---|---|
| Frequency | 60.0 Hz |
| Standby power | 250 kW |
| Prime power | 227 kW |
| Emissions | Tier-3 |
| Controller | Digital auto-start microprocessor based control panel with remote start capability |
| Oil capacity | 30.0 L |
| Alternator | Stamford/AvK HCI434 (4-pole, Class H insulation) |
| Voltage options | 120/240 V, 120/208 V, 277/480 V, 347/600 V |
| Phase | 1 |
| Rated current | 1040 A |
| Power factor | 1 |
| Circuit breaker | 947 A |
| Battery group | 4D |
| Battery cranking | 1000 CCA |
| Battery voltage | 12 V |
| Battery quantity | 1 |
| Coolant capacity | 44 L |
| Max ambient | 40 °C |
| Dimensions (L×W×H) | 3073×1219×1689 mm |
| Dry weight | 3034 kg |
| Fuel tank | 1685.9 L |
| Tank runtime | 24 hr |
Engine
| Oil capacity | 30.0 L |
|---|---|
| Coolant capacity | 44.0 L |
| Displacement | 12.78 L |
| Aspiration | Turbocharged |
| Rated speed | 1800 rpm |
Same engine, other brands
1 brandThe Volvo Penta TAD1350GE in this set also powers 1 generator set sold under 1 other brand. Service parts and maintenance intervals for the engine are shared; enclosure, alternator, controller and ratings are not.
| Brand | Models |
|---|---|
| Volvo Penta | TAD1350GE |
Common questions
How many kW is the Simson-Maxwell SVW250 T6-T3?
The Simson-Maxwell SVW250 T6-T3 is rated 250 kW standby.
Which engine powers the Simson-Maxwell SVW250 T6-T3?
The Simson-Maxwell SVW250 T6-T3 is powered by the Volvo Penta TAD1350GE engine.
Is the Simson-Maxwell SVW250 T6-T3 diesel or gas?
The Simson-Maxwell SVW250 T6-T3 runs on Diesel.
What is the oil capacity of the Simson-Maxwell SVW250 T6-T3?
The Volvo Penta TAD1350GE engine in the Simson-Maxwell SVW250 T6-T3 has an oil capacity of 30.0 liters.
What is the coolant capacity of the Simson-Maxwell SVW250 T6-T3?
The Simson-Maxwell SVW250 T6-T3 cooling system holds 44 liters (11.6 US gallons) for the radiator system including the engine, per the manufacturer specification sheet.
What is the prime power rating of the Simson-Maxwell SVW250 T6-T3?
The Simson-Maxwell SVW250 T6-T3 is rated 227 kW prime, against 250 kW standby.
How much does the Simson-Maxwell SVW250 T6-T3 weigh?
The Simson-Maxwell SVW250 T6-T3 has a dry weight of 3034 kg (6689 lb).
How big is the fuel tank on the Simson-Maxwell SVW250 T6-T3?
The Simson-Maxwell SVW250 T6-T3 has a 1685.9 liter (445 US gallon) fuel tank, giving about 24 hours of runtime.
What voltage does the Simson-Maxwell SVW250 T6-T3 produce?
The Simson-Maxwell SVW250 T6-T3 is offered in 120/240 V, 120/208 V, 277/480 V, 347/600 V, 1-phase.
How many cold cranking amps does the Simson-Maxwell SVW250 T6-T3 require?
The Simson-Maxwell SVW250 T6-T3 uses 1 battery, 12 V each, 1000 CCA, group 4D, per the manufacturer specification sheet.
What alternator comes on the Simson-Maxwell SVW250 T6-T3?
The Simson-Maxwell SVW250 T6-T3 uses a Stamford/AvK HCI434 alternator. It has 4 poles. Insulation class H.
Parts
1| Part # | Description | Qty | System | |
|---|---|---|---|---|
| 7748641 | injector cables | 1 | Service part / kit | Amazon eBay |
Service, wear & replacement parts referenced for this model and its engine — confirm the exact part for your serial number. See the full parts catalog to search and cross-reference.
Fuel consumption
| Rating | Load | L/h | gal/h |
|---|---|---|---|
| Prime | 35.9 | 9.48 | |
| Prime | 25% | 23.7 | 6.26 |
| Prime | 75% | 49.9 | 13.18 |
| Prime | 100% | 64.8 | 17.12 |
| Standby | 25% | 24.4 | 6.45 |
| Standby | 50% | 37.9 | 10.01 |
| Standby | 75% | 54.3 | 14.34 |
| Standby | 100% | 70.2 | 18.54 |
Available documents
This page was generated from the 1 manufacturer document above by automated extraction; every figure shown is copied from one of them. How the data is compiled.