Specifications
| Fuel | Diesel |
|---|---|
| Frequency | 60.0 Hz |
| Standby power | 99 kW |
| Prime power | 89 kW |
| Emissions | Tier-3 |
| Controller | Digital auto-start microprocessor based control panel with remote start capability |
| Oil capacity | 11.0 L |
| Alternator | Stamford/AvK UCI274 (4-pole, Class H insulation) |
| Voltage options | 120/240 V, 120/208 V, 277/480 V, 347/600 V |
| Phase | 1 |
| Rated current | 414 A |
| Power factor | 1 |
| Circuit breaker | 370 A |
| Battery group | 4D, 12V |
| Battery cranking | 1000 CCA |
| Battery voltage | 12 V |
| Battery quantity | 1 |
| Coolant capacity | 22 L |
| Max ambient | 40 °C |
| Dimensions (L×W×H) | 2286×977×1371 mm |
| Dry weight | 1325 kg |
Engine
| Oil capacity | 11.0 L |
|---|---|
| Coolant capacity | 22.0 L |
| Displacement | 4.76 L |
| Aspiration | Turbocharged |
| Rated speed | 1500 rpm |
Common questions
What is the power rating of the Simson-Maxwell SVW100 T6-T3?
The Simson-Maxwell SVW100 T6-T3 is rated 99 kW standby.
What engine does the Simson-Maxwell SVW100 T6-T3 use?
The Simson-Maxwell SVW100 T6-T3 is powered by the Volvo Penta TAD551GE engine.
What fuel does the Simson-Maxwell SVW100 T6-T3 use?
The Simson-Maxwell SVW100 T6-T3 runs on Diesel.
What is the oil capacity of the Simson-Maxwell SVW100 T6-T3?
The Volvo Penta TAD551GE engine in the Simson-Maxwell SVW100 T6-T3 has an oil capacity of 11.0 liters.
What alternator does the Simson-Maxwell SVW100 T6-T3 use?
The Simson-Maxwell SVW100 T6-T3 uses a Stamford/AvK UCI274 alternator. It has 4 poles. Insulation class H.
Fuel consumption
| Rating | Load | L/h | gal/h |
|---|---|---|---|
| Prime | 17.9 | ||
| Prime | 25% | 11.0 | |
| Prime | 75% | 24.4 | |
| Prime | 100% | 28.4 | |
| Standby | 25% | 11.4 | |
| Standby | 50% | 19.9 | |
| Standby | 75% | 23.8 | |
| Standby | 100% | 28.0 |