The Simson-Maxwell SVW100 T6-T3 is a 99 kW Diesel standby generator set powered by a Volvo Penta TAD551GE engine. It is available at 120/240 V, 120/208 V, 277/480 V and 347/600 V, single-phase, 60 Hz and rated 414 A. It holds about 11 L (2.9 gal) of oil and 22 L (5.8 gal) of coolant, with a maximum ambient rating of 40 °C. Starting uses 1 group-4 battery rated 1000 CCA at 12 V. The set measures 2286×977.9×1371.6 mm (90.0×38.5×54.0 in) and weighs about 1325.1 kg (2921 lb). The same TAD551GE engine also powers generator sets from Volvo Penta.

99 kW
Standby
4.76 L
Displacement
11.0 L
Oil capacity
1
Document types

Typical fuel consumption for 95–100 kW Diesel generators →

Compare with other 95–100 kW Diesel generators →

Specifications

FuelDiesel
Frequency60.0 Hz
Standby power99 kW
Prime power89 kW
EmissionsTier-3
ControllerDigital auto-start microprocessor based control panel with remote start capability
Oil capacity11.0 L
AlternatorStamford/AvK UCI274 (4-pole, Class H insulation)
Voltage options120/240 V, 120/208 V, 277/480 V, 347/600 V
Phase1
Rated current414 A
Power factor1
Circuit breaker370 A
Battery group4D, 12V
Battery cranking1000 CCA
Battery voltage12 V
Battery quantity1
Coolant capacity22 L
Max ambient40 °C
Dimensions (L×W×H)2286×977×1371 mm
Dry weight1325 kg

Engine

Volvo Penta TAD551GE
Oil capacity11.0 L
Coolant capacity22.0 L
Displacement4.76 L
AspirationTurbocharged
Rated speed1800 rpm

Same engine, other brands

1 brand

The Volvo Penta TAD551GE in this set also powers 1 generator set sold under 1 other brand. Service parts and maintenance intervals for the engine are shared; enclosure, alternator, controller and ratings are not.

BrandModels
Volvo PentaTAD551GE

Common questions

How many kW is the Simson-Maxwell SVW100 T6-T3?

The Simson-Maxwell SVW100 T6-T3 is rated 99 kW standby.

What engine is in the Simson-Maxwell SVW100 T6-T3?

The Simson-Maxwell SVW100 T6-T3 is powered by the Volvo Penta TAD551GE engine.

What fuel does the Simson-Maxwell SVW100 T6-T3 use?

The Simson-Maxwell SVW100 T6-T3 runs on Diesel.

How much oil does the Simson-Maxwell SVW100 T6-T3 take?

The Volvo Penta TAD551GE engine in the Simson-Maxwell SVW100 T6-T3 has an oil capacity of 11.0 liters.

How much coolant does the Simson-Maxwell SVW100 T6-T3 hold?

The Simson-Maxwell SVW100 T6-T3 cooling system holds 22 liters (5.8 US gallons) for the radiator system including the engine, per the manufacturer specification sheet.

What is the prime power rating of the Simson-Maxwell SVW100 T6-T3?

The Simson-Maxwell SVW100 T6-T3 is rated 89 kW prime, against 99 kW standby.

How much does the Simson-Maxwell SVW100 T6-T3 weigh?

The Simson-Maxwell SVW100 T6-T3 has a dry weight of 1325 kg (2921 lb).

What voltages is the Simson-Maxwell SVW100 T6-T3 available in?

The Simson-Maxwell SVW100 T6-T3 is offered in 120/240 V, 120/208 V, 277/480 V, 347/600 V, 1-phase.

What size battery does the Simson-Maxwell SVW100 T6-T3 need?

The Simson-Maxwell SVW100 T6-T3 uses 1 battery, 12 V each, 1000 CCA, group 4D, 12V, per the manufacturer specification sheet.

Which alternator is fitted to the Simson-Maxwell SVW100 T6-T3?

The Simson-Maxwell SVW100 T6-T3 uses a Stamford/AvK UCI274 alternator. It has 4 poles. Insulation class H.

Fuel consumption

RatingLoadL/hgal/h
Prime17.94.73
Prime25%11.02.91
Prime75%24.46.45
Prime100%28.47.5
Standby25%11.43.01
Standby50%19.95.26
Standby75%23.86.29
Standby100%28.07.4