Specifications
| Fuel | Diesel |
|---|---|
| Frequency | 60.0 Hz |
| Standby power | 99 kW |
| Prime power | 89 kW |
| Emissions | Tier-3 |
| Controller | Digital auto-start microprocessor based control panel with remote start capability |
| Oil capacity | 11.0 L |
| Alternator | Stamford/AvK UCI274 (4-pole, Class H insulation) |
| Voltage options | 120/240 V, 120/208 V, 277/480 V, 347/600 V |
| Phase | 1 |
| Rated current | 414 A |
| Power factor | 1 |
| Circuit breaker | 370 A |
| Battery group | 4D, 12V |
| Battery cranking | 1000 CCA |
| Battery voltage | 12 V |
| Battery quantity | 1 |
| Coolant capacity | 22 L |
| Max ambient | 40 °C |
| Dimensions (L×W×H) | 2286×977×1371 mm |
| Dry weight | 1325 kg |
Engine
| Oil capacity | 11.0 L |
|---|---|
| Coolant capacity | 22.0 L |
| Displacement | 4.76 L |
| Aspiration | Turbocharged |
| Rated speed | 1800 rpm |
Same engine, other brands
1 brandThe Volvo Penta TAD551GE in this set also powers 1 generator set sold under 1 other brand. Service parts and maintenance intervals for the engine are shared; enclosure, alternator, controller and ratings are not.
| Brand | Models |
|---|---|
| Volvo Penta | TAD551GE |
Common questions
How many kW is the Simson-Maxwell SVW100 T6-T3?
The Simson-Maxwell SVW100 T6-T3 is rated 99 kW standby.
What engine is in the Simson-Maxwell SVW100 T6-T3?
The Simson-Maxwell SVW100 T6-T3 is powered by the Volvo Penta TAD551GE engine.
What fuel does the Simson-Maxwell SVW100 T6-T3 use?
The Simson-Maxwell SVW100 T6-T3 runs on Diesel.
How much oil does the Simson-Maxwell SVW100 T6-T3 take?
The Volvo Penta TAD551GE engine in the Simson-Maxwell SVW100 T6-T3 has an oil capacity of 11.0 liters.
How much coolant does the Simson-Maxwell SVW100 T6-T3 hold?
The Simson-Maxwell SVW100 T6-T3 cooling system holds 22 liters (5.8 US gallons) for the radiator system including the engine, per the manufacturer specification sheet.
What is the prime power rating of the Simson-Maxwell SVW100 T6-T3?
The Simson-Maxwell SVW100 T6-T3 is rated 89 kW prime, against 99 kW standby.
How much does the Simson-Maxwell SVW100 T6-T3 weigh?
The Simson-Maxwell SVW100 T6-T3 has a dry weight of 1325 kg (2921 lb).
What voltages is the Simson-Maxwell SVW100 T6-T3 available in?
The Simson-Maxwell SVW100 T6-T3 is offered in 120/240 V, 120/208 V, 277/480 V, 347/600 V, 1-phase.
What size battery does the Simson-Maxwell SVW100 T6-T3 need?
The Simson-Maxwell SVW100 T6-T3 uses 1 battery, 12 V each, 1000 CCA, group 4D, 12V, per the manufacturer specification sheet.
Which alternator is fitted to the Simson-Maxwell SVW100 T6-T3?
The Simson-Maxwell SVW100 T6-T3 uses a Stamford/AvK UCI274 alternator. It has 4 poles. Insulation class H.
Fuel consumption
| Rating | Load | L/h | gal/h |
|---|---|---|---|
| Prime | 17.9 | 4.73 | |
| Prime | 25% | 11.0 | 2.91 |
| Prime | 75% | 24.4 | 6.45 |
| Prime | 100% | 28.4 | 7.5 |
| Standby | 25% | 11.4 | 3.01 |
| Standby | 50% | 19.9 | 5.26 |
| Standby | 75% | 23.8 | 6.29 |
| Standby | 100% | 28.0 | 7.4 |