Specifications
| Fuel | Diesel |
|---|---|
| Frequency | 60.0 Hz |
| Standby power | 147 kW |
| Standby kVA | 614 |
| Prime power | 140 kW |
| Emissions | Tier-4I |
| Controller | Digital auto-start microprocessor based control panel with remote start capability |
| Oil capacity | 20.0 L |
| Alternator | Stamford/AvK UCI274 (4-pole, Class H insulation) |
| Voltage options | 120/240 V, 120/208 V, 277/480 V, 347/600 V |
| Phase | 1 |
| Rated current | 614 A |
| Power factor | 1 |
| Circuit breaker | 614 A |
| Battery group | 4D, 12V |
| Battery voltage | 12 V |
| Battery quantity | 1 |
| Coolant capacity | 34 L |
| Max ambient | 40 °C |
| Dimensions (L×W×H) | 2590×889×1447 mm |
| Dry weight | 1628 kg |
| Fuel tank | 1206.5 L |
| Tank runtime | 24 hr |
Engine
| Oil capacity | 20.0 L |
|---|---|
| Coolant capacity | 34.0 L |
| Displacement | 7.1 L |
| Aspiration | Turbocharged |
| Rated speed | 1800 rpm |
Common questions
What size generator is the Simson-Maxwell SDW140 T6-T4?
The Simson-Maxwell SDW140 T6-T4 is rated 147 kW standby (614.0 kVA).
What engine does the Simson-Maxwell SDW140 T6-T4 use?
The Simson-Maxwell SDW140 T6-T4 is powered by the Deutz TCD2013L062V engine.
What fuel does the Simson-Maxwell SDW140 T6-T4 use?
The Simson-Maxwell SDW140 T6-T4 runs on Diesel.
What's the oil capacity on a Simson-Maxwell SDW140 T6-T4?
The Deutz TCD2013L062V engine in the Simson-Maxwell SDW140 T6-T4 has an oil capacity of 20.0 liters.
What is the coolant capacity of the Simson-Maxwell SDW140 T6-T4?
The Simson-Maxwell SDW140 T6-T4 cooling system holds 34 liters (9.0 US gallons) for the radiator system including the engine, per the manufacturer specification sheet.
What is the prime power rating of the Simson-Maxwell SDW140 T6-T4?
The Simson-Maxwell SDW140 T6-T4 is rated 140 kW prime (581 kVA), against 147 kW standby.
How much does the Simson-Maxwell SDW140 T6-T4 weigh?
The Simson-Maxwell SDW140 T6-T4 has a dry weight of 1628 kg (3590 lb).
How big is the fuel tank on the Simson-Maxwell SDW140 T6-T4?
The Simson-Maxwell SDW140 T6-T4 has a 1206.5 liter (319 US gallon) fuel tank, giving about 24 hours of runtime.
What voltages is the Simson-Maxwell SDW140 T6-T4 available in?
The Simson-Maxwell SDW140 T6-T4 is offered in 120/240 V, 120/208 V, 277/480 V, 347/600 V, 1-phase.
How many cold cranking amps does the Simson-Maxwell SDW140 T6-T4 require?
The Simson-Maxwell SDW140 T6-T4 uses 1 battery, 12 V each, group 4D, 12V, per the manufacturer specification sheet.
Which alternator is fitted to the Simson-Maxwell SDW140 T6-T4?
The Simson-Maxwell SDW140 T6-T4 uses a Stamford/AvK UCI274 alternator. It has 4 poles. Insulation class H.
Fuel consumption
| Rating | Load | L/h | gal/h |
|---|---|---|---|
| Prime | 27.4 | 7.24 | |
| Prime | 25% | 14.4 | 3.8 |
| Prime | 75% | 38.2 | 10.09 |
| Prime | 100% | 45.7 | 12.07 |
| Standby | 25% | 15.8 | 4.17 |
| Standby | 50% | 30.1 | 7.95 |
| Standby | 75% | 42.0 | 11.1 |
| Standby | 100% | 50.3 | 13.29 |