Home›Seneca›Seneca 1000GGS2

Seneca 1000GGS2 Generator Set

The Seneca 1000GGS2 is a 1000 kW (1250 kVA) NATURAL GAS standby generator set powered by a Power Solutions International HD 53L engine. It is available at 120 V, 208 V, 347 V and 600 V, 3-phase, 60 Hz and rated 3469.65 A. It holds about 171 L (45.2 gal) of oil and 55 L (14.5 gal) of coolant. Starting uses 1 group-24 battery rated 1050 CCA at 24 V.

1000 kW
Standby
53.0 L
Displacement
171.0 L
Oil capacity
1
Document types

Compare with other 1000–1005 kW Natural Gas generators →

Specifications

FuelNATURAL GAS
Frequency60.0 Hz
Standby power1000 kW
Standby kVA1250
ControllerMicroprocessor based controller
Oil capacity171.0 L
AlternatorStamford/AvK Brushless, 4 pole, Revolving field
Voltage options120 V, 208 V, 347 V, 600 V
Phase3
Rated current3469.65 A
Circuit breaker1202.81 A
Battery group24 Volt
Battery cranking1050 CCA
Battery voltage24 V
Battery quantity1
Coolant capacity55 L

Engine

Power Solutions International HD 53L
Oil capacity171.0 L
Displacement53.0 L
AspirationCharged Cooled Forced Induction
Rated speed1800 rpm

Common questions

What size generator is the Seneca 1000GGS2?

The Seneca 1000GGS2 is rated 1000 kW standby (1250.0 kVA).

What engine is in the Seneca 1000GGS2?

The Seneca 1000GGS2 is powered by the Power Solutions International HD 53L engine.

What kind of fuel does the Seneca 1000GGS2 run on?

The Seneca 1000GGS2 runs on NATURAL GAS.

What is the oil capacity of the Seneca 1000GGS2?

The Power Solutions International HD 53L engine in the Seneca 1000GGS2 has an oil capacity of 171.0 liters.

What is the coolant capacity of the Seneca 1000GGS2?

The Seneca 1000GGS2 cooling system holds 55 liters (14.5 US gallons) for the radiator system including the engine, per the manufacturer specification sheet.

What voltage does the Seneca 1000GGS2 produce?

The Seneca 1000GGS2 is offered in 120 V, 208 V, 347 V, 600 V, 3-phase.

What size battery does the Seneca 1000GGS2 need?

The Seneca 1000GGS2 uses 1 battery, 24 V each, 1050 CCA, group 24 Volt, per the manufacturer specification sheet.

Which alternator is fitted to the Seneca 1000GGS2?

The Seneca 1000GGS2 uses a Stamford/AvK Brushless, 4 pole, Revolving field alternator.

Fuel consumption

RatingLoadL/hgal/h
Standby25%193.088.0
Standby50%311.0141.0
Standby75%435.0197.0
Standby100%565.0256.0

Available documents

Spec sheet — 1000GGS2 (Seneca)

This page was generated from the 1 manufacturer document above by automated extraction; every figure shown is copied from one of them. How the data is compiled.