Specifications
| Fuel | diesel |
|---|---|
| Frequency | 50.0 Hz |
| Standby power | 183 kW |
| Standby kVA | 229 |
| Prime power | 166 kW |
| Emissions | Stage 2 |
| Oil capacity | 26.4 L |
| Power factor | 0.8 |
| Dimensions (L×W×H) | 1822×875×1369 mm |
| Dry weight | 895 kg |
Engine
| Oil capacity | 26.4 L |
|---|---|
| Coolant capacity | 37.2 L |
| Displacement | 8.7 L |
| Aspiration | Turbocharged, air-to-air chargecooled |
| Rated speed | 1500 rpm |
Filters for the Perkins 1306C-E87TAG3
2Engine-mounted filters the filter manufacturers list for this engine family. These come from the engine, not from this generator set’s own parts list, so confirm against your serial number before ordering.
Listed for this engine in only one kind of machine, so they may depend on how the engine was installed:
| System | Filter | Description | Cross-references | |
|---|---|---|---|---|
| Oil filter | P550367 | Lube Filter, Spin-On Full Flow | PERKINS 26540244, PERKINS P26540238, BALDWIN B7030, LOESING 025153 | buy |
| Oil filter | P502107 | Lube Filter, Spin-On Full Flow | NAPA 1374, LEYLAND-DAF (LDV) 12G24OO, MANITOU 136508, ORENSTEIN & KOPPEL 1499499 | buy |
Maintenance & consumables
for the Perkins 1306C-E87TAG3| Item | Spec | Capacity | Part # | Interval | |
|---|---|---|---|---|---|
| Oil filter | — | 450 hr | |||
| Oil | — | 450 hr |
Service intervals
2| Item | Action | Hours | Months | Notes |
|---|---|---|---|---|
| oil and filter | Change | 450 hr | 1300 Series EDi - oil and filter changes at 450 hours reduce down time | |
| service interval | Other | 500 hr | 1100C range - 500 hour service intervals |
Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.
Recommended fluids
| Fluid | Grade | Standard | Ambient | Capacity | Notes |
|---|---|---|---|---|---|
| Engine oil | API CH4/ACEA E5 | 1100 Series (1103C/1104C) | |||
| Engine oil | 15W40 | ACEA E3 or API CG4 | 1300 Series EDi | ||
| Engine oil | multi-grade oil | API-CH4/CI4 | 1106D-E66TAG | ||
| Engine oil | single or multigrade oil | ACEA E1 E2 or CD/SD | 1000 Series | ||
| Fuel | BS 2869 Part 2 1998 Class A2 or ASTM D975 D2 | 1000/1300 Series |
Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.
Common questions
What size generator is the Perkins 1306C-E87TAG3?
The Perkins 1306C-E87TAG3 is rated 183 kW standby (229.0 kVA).
What engine does the Perkins 1306C-E87TAG3 use?
The Perkins 1306C-E87TAG3 is powered by the Perkins 1306C-E87TAG3 engine.
What kind of fuel does the Perkins 1306C-E87TAG3 run on?
The Perkins 1306C-E87TAG3 runs on diesel.
What is the oil capacity of the Perkins 1306C-E87TAG3?
The Perkins 1306C-E87TAG3 engine in the Perkins 1306C-E87TAG3 has an oil capacity of 26.4 liters.
How much coolant does the Perkins 1306C-E87TAG3 hold?
The Perkins 1306C-E87TAG3 cooling system holds 37.2 liters (9.8 US gallons) for the engine, per the manufacturer specification sheet.
What is the continuous rating of the Perkins 1306C-E87TAG3?
The Perkins 1306C-E87TAG3 is rated 166 kW prime (208 kVA), against 183 kW standby.
What is the dry weight of the Perkins 1306C-E87TAG3?
The Perkins 1306C-E87TAG3 has a dry weight of 895 kg (1973 lb).
Available documents
This page was generated from the 18 manufacturer documents above by automated extraction; every figure shown is copied from one of them. How the data is compiled.