Home›MTU›MTU DS 3315 D6S RW

MTU DS 3315 D6S RW Generator Set

The MTU DS 3315 D6S RW is a 3315 kW Diesel standby generator set powered by a MTU 20V 4000 G83L engine. It operates at 60 Hz. It holds about 390 L (103.0 gal) of oil and 205 L (54.2 gal) of coolant. The same 20V 4000 G83L engine also powers generator sets from Hipower.

3315 kW
Standby
95.4 L
Displacement
390.0 L
Oil capacity
1
Document types

How to read your MTU serial & model number →

Specifications

FuelDiesel
Frequency60.0 Hz
Standby power3315 kW
ControllerDGC-2020
Oil capacity390.0 L
AlternatorMarathon MAGNAMAX, MAGNAPOWER (Class H insulation)

Engine

MTU 20V 4000 G83L
Oil capacity390.0 L
Coolant capacity205.0 L
Displacement95.4 L
AspirationExhaust turbocharging (ETC) with charge-air cooling (CAC)
Rated speed1800 rpm

Same engine, other brands

1 brand

The MTU 20V 4000 G83L in this set also powers 1 generator set sold under 1 other brand. Service parts and maintenance intervals for the engine are shared; enclosure, alternator, controller and ratings are not.

BrandModels
HipowerHMW 3180 T6

Filters & service parts

model family
ItemSpecCapacityPart #Interval
Air filterTwo-stage engine air filter operating in medium to heavy dust conditions; RadialSeal technology; filter insert and filter element combined; mounted filter service indicator; removing of 99.99% of dust and dirt particulate—
CoolantFlow rate of 38 l/min (10 GPM); adjustable thermostat from 32 to 55 C (90 to 130 F); single or 3-phase system; UL-C/US certificate E250789 (60 Hz models); CE compliant (50 Hz models)—

Compiled from this model's family documentation — may include parts for closely-related variants. Confirm the exact part for your serial number.

Service specifications

1
TypeItemValueUnitCondition
TemperatureJacket water heater adjustable thermostat32 to 55°C

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Voltage reconnection

VoltagePhaseConnectionLeadsNotes
380/400/415Standard scope voltage, 50 Hz (S1600/S2000/S4000)
380/440/480Standard scope voltage, 60 Hz (S1600/S2000/S4000)
400/230Standard scope voltage, 1600 series, 50 Hz
440/480Alternator voltages, 60 Hz
480/277Standard scope voltage, 1600 series, 60 Hz

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Common questions

What is the power rating of the MTU DS 3315 D6S RW?

The MTU DS 3315 D6S RW is rated 3315 kW standby.

What engine does the MTU DS 3315 D6S RW use?

The MTU DS 3315 D6S RW is powered by the MTU 20V 4000 G83L engine.

What fuel does the MTU DS 3315 D6S RW use?

The MTU DS 3315 D6S RW runs on Diesel.

What's the oil capacity on a MTU DS 3315 D6S RW?

The MTU 20V 4000 G83L engine in the MTU DS 3315 D6S RW has an oil capacity of 390.0 liters.

How much coolant does the MTU DS 3315 D6S RW hold?

The MTU DS 3315 D6S RW cooling system holds 205 liters (54.2 US gallons) for the engine, per the manufacturer specification sheet.

What alternator comes on the MTU DS 3315 D6S RW?

The MTU DS 3315 D6S RW uses a Marathon MAGNAMAX, MAGNAPOWER alternator. Insulation class H.

Available documents

Reference — Product MTU (MTU)

This page was generated from the 1 manufacturer document above by automated extraction; every figure shown is copied from one of them. How the data is compiled.

Other sets with this engine