Specifications
| Fuel | Diesel |
|---|---|
| Frequency | 60.0 Hz |
| Standby power | 1200 kW |
| Emissions | EPA Tier 2 |
| Controller | DGC-2020 |
| Oil capacity | 130.0 L |
| Alternator | Marathon MAGNAMAX, MAGNAPOWER (Class H insulation) |
Engine
| Oil capacity | 130.0 L |
|---|---|
| Displacement | 35.8 L |
| Aspiration | Air charge air cooling |
| Rated speed | 1800 rpm |
Filters & service parts
model family| Item | Spec | Capacity | Part # | Interval | |
|---|---|---|---|---|---|
| Air filter | Two-stage engine air filter operating in medium to heavy dust conditions; RadialSeal technology; filter insert and filter element combined; mounted filter service indicator; removing of 99.99% of dust and dirt particulate | — | |||
| Coolant | Flow rate of 38 l/min (10 GPM); adjustable thermostat from 32 to 55 C (90 to 130 F); single or 3-phase system; UL-C/US certificate E250789 (60 Hz models); CE compliant (50 Hz models) | — |
Compiled from this model's family documentation — may include parts for closely-related variants. Confirm the exact part for your serial number.
Service specifications
1| Type | Item | Value | Unit | Condition |
|---|---|---|---|---|
| Temperature | Jacket water heater adjustable thermostat | 32 to 55 | °C |
Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.
Voltage reconnection
| Voltage | Phase | Connection | Leads | Notes |
|---|---|---|---|---|
| 380/400/415 | Standard scope voltage, 50 Hz (S1600/S2000/S4000) | |||
| 380/440/480 | Standard scope voltage, 60 Hz (S1600/S2000/S4000) | |||
| 400/230 | Standard scope voltage, 1600 series, 50 Hz | |||
| 440/480 | Alternator voltages, 60 Hz | |||
| 480/277 | Standard scope voltage, 1600 series, 60 Hz |
Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.
Common questions
What size generator is the MTU DS 1200 D6S RA?
The MTU DS 1200 D6S RA is rated 1200 kW standby.
Which engine powers the MTU DS 1200 D6S RA?
The MTU DS 1200 D6S RA is powered by the MTU 18V 2000 G85 engine.
What fuel does the MTU DS 1200 D6S RA use?
The MTU DS 1200 D6S RA runs on Diesel.
What is the oil capacity of the MTU DS 1200 D6S RA?
The MTU 18V 2000 G85 engine in the MTU DS 1200 D6S RA has an oil capacity of 130.0 liters.
What alternator does the MTU DS 1200 D6S RA use?
The MTU DS 1200 D6S RA uses a Marathon MAGNAMAX, MAGNAPOWER alternator. Insulation class H.