Specifications
| Fuel | diesel |
|---|---|
| Frequency | 50.0 Hz |
| Standby power | 2660 kW |
| Standby kVA | 2640 |
| Prime power | 2112 kW |
| Emissions | NEA (ORDE) optimized |
| Controller | Basler controller,Deif controller |
| Oil capacity | 390.0 L |
| Alternator | Leroy-Somer LSA53.2 M7 |
| Voltage options | 380 V, 400 V, 415 V, 11 V |
| Phase | 3 |
| Rated current | 4254 A |
| Power factor | 0.8 |
| Circuit breaker | [4011, 3890, 3673, 3811, 3695, 3561, 4041, 3905, 3782, 3666, 3645, 138, 134] A |
| Coolant capacity | 255 L |
| Max ambient | 40 °C |
| Dimensions (L×W×H) | 5760×1887×2332 mm |
| Dry weight | 16919 kg |
Engine
| Oil capacity | 390.0 L |
|---|---|
| Coolant capacity | 255.0 L |
| Displacement | 95.4 L |
| Aspiration | water charge air cooling |
| Rated speed | 1500 rpm |
Maintenance & consumables
for the MTU 20V4000G14F| Item | Spec | Capacity | Part # | Interval | |
|---|---|---|---|---|---|
| Air filter | Dry | — | find | ||
| Fuel filter | — | find | |||
| Oil filter | — | find | |||
| Belt | — | find | |||
| Coolant | 205.0 l | — | |||
| Oil | 390.0 l | — |
Common questions
What is the power rating of the MTU 20V4000 DS2750?
The MTU 20V4000 DS2750 is rated 2660 kW standby (2640.0 kVA).
What engine does the MTU 20V4000 DS2750 use?
The MTU 20V4000 DS2750 is powered by the MTU 20V4000G14F engine.
What fuel does the MTU 20V4000 DS2750 use?
The MTU 20V4000 DS2750 runs on diesel.
What is the oil capacity of the MTU 20V4000 DS2750?
The MTU 20V4000G14F engine in the MTU 20V4000 DS2750 has an oil capacity of 390.0 liters.
What alternator does the MTU 20V4000 DS2750 use?
The MTU 20V4000 DS2750 uses a Leroy-Somer LSA53.2 M7 alternator.
Fuel consumption
| Rating | Load | L/h | gal/h |
|---|---|---|---|
| 50% | 320.7 | ||
| 75% | 457.0 | ||
| 100% | 580.2 | ||
| Prime | |||
| Prime | 50% | 279.6 | |
| Prime | 75% | 387.7 | |
| Prime | 100% | 508.9 | |
| Standby | |||
| Standby | 50% | 293.0 | |
| Standby | 75% | 419.9 | |
| Standby | 100% | 554.0 |