Home›MTU›MTU 18V 2000 G26F

MTU 18V 2000 G26F Generator Set

The MTU 18V 2000 G26F is a 1102 kW (1250 kVA) Diesel standby generator set powered by a MTU 18V2000G26F engine. It is available at 380 V, 400 V and 415 V, 3-phase, 50 Hz and rated 1899 A. It holds about 110 L (29.1 gal) of oil and 73 L (19.3 gal) of coolant, with a maximum ambient rating of not specified °C. Starting uses 1 group-not specified battery at 24 V. The set measures 4720×1990×2200 mm (185.8×78.3×86.6 in), weighs about 7700 kg (16976 lb) and produces not specified dBA at not specified m. An integrated tank holds not specified L (None gal), roughly not specified hours of runtime.

1102 kW
Standby
40.2 L
Displacement
110.0 L
Oil capacity
2
Document types

How to read your MTU serial & model number →

Compare with other 1100–1105 kW Diesel generators →

Specifications

FuelDiesel
Frequency50.0 Hz
Standby power1102 kW
Standby kVA1250
Prime power1000 kW
EmissionsTier 2
ControllerBasler controller, Deif controller
Oil capacity110.0 L
AlternatorLeroy-Somer LSA 50.2 L7/L8
Voltage options380 V, 400 V, 415 V
Phase3-phase
Rated current1899 A
Power factor0.8
Circuit breaker1899 A
Battery groupnot specified
Battery voltage24 V
Battery quantity1
Coolant capacity73 L
Max ambientnot specified °C
Dimensions (L×W×H)4720×1990×2200 mm
Dry weight7700 kg
Tank runtimenot specified hr

Engine

MTU 18V2000G26F
Oil capacity122.0 L
Coolant capacity73.0 L
Displacement40.2 L
Aspiration4-cycle
Rated speed1500 rpm

Filters for the MTU 18V2000G26F

1

Engine-mounted filters the filter manufacturers list for this engine family. These come from the engine, not from this generator set’s own parts list, so confirm against your serial number before ordering.

Listed for this engine in only one kind of machine, so they may depend on how the engine was installed:

SystemFilterDescriptionCross-references
Fuel / water separatorP502404Fuel Filter, Water Separator Spin-OnMTU 0020920601, MTU 20920601, BALDWIN BF7987, SDMO 330510032 KuduParts $18.00 FridayParts $20.68

Common questions

What is the power rating of the MTU 18V 2000 G26F?

The MTU 18V 2000 G26F is rated 1102 kW standby (1250.0 kVA).

Which engine powers the MTU 18V 2000 G26F?

The MTU 18V 2000 G26F is powered by the MTU 18V2000G26F engine.

What fuel does the MTU 18V 2000 G26F use?

The MTU 18V 2000 G26F runs on Diesel.

What is the oil capacity of the MTU 18V 2000 G26F?

The MTU 18V2000G26F engine in the MTU 18V 2000 G26F has an oil capacity of 122.0 liters.

What is the coolant capacity of the MTU 18V 2000 G26F?

The MTU 18V 2000 G26F cooling system holds 73 liters (19.3 US gallons) for the radiator system including the engine, per the manufacturer specification sheet.

What is the prime power rating of the MTU 18V 2000 G26F?

The MTU 18V 2000 G26F is rated 1000 kW prime (1250 kVA), against 1102 kW standby.

What is the dry weight of the MTU 18V 2000 G26F?

The MTU 18V 2000 G26F has a dry weight of 7700 kg (16975 lb).

What voltages is the MTU 18V 2000 G26F available in?

The MTU 18V 2000 G26F is offered in 380 V, 400 V, 415 V, 3-phase-phase.

What size battery does the MTU 18V 2000 G26F need?

The MTU 18V 2000 G26F uses 1 battery, 24 V each, group not specified, per the manufacturer specification sheet.

What alternator comes on the MTU 18V 2000 G26F?

The MTU 18V 2000 G26F uses a Leroy-Somer LSA 50.2 L7/L8 alternator.

Fuel consumption

RatingLoadL/hgal/h
Prime50%130.0196.0
Prime75%197.0198.0
Prime100%264.0199.0
Standby50%130.0196.0
Standby75%188.0189.0
Standby100%251.0189.0

Available documents

Engine spec — 32310301 MTU Gendrive spec 12V16V18V2000Gx06 3A 3B 3G A2A (MTU)Engine spec — 3239201 MTU Gendrive spec 2000G 06 3D3E A2A (MTU)Spec sheet — 1250-2 (MTU)Spec sheet — 1250 (MTU)Spec sheet — 3239571 OE spec MTU18V2000DS1400 3B 50Hz 1 15 (MTU)Reference — 18V2000G26F FCO (ctm.it)Reference — 18V2000G26F NEA T2 (ctm.it)Reference — 18V2000G26F NOx (ctm.it)Reference — 3239571 PG spec 18V2000DS1400 1250kVA 3B FC NOx 50Hz (MTU)Reference — 3239771 PG spec 18V2000DS1400 1250kVA 3E FC 50Hz (MTU)Reference — 3239771 PG spec 18V2000DS1400 1250kVA 3E FC NOx 50Hz (MTU)Reference — 3239791 PG spec 18V2000DS1400 1250kVA 3F FC 50Hz (MTU)Reference — 3239791 PG spec 18V2000DS1400 1250kVA 3F FC NOx 50Hz (MTU)Reference — 3239811 PG spec 18V2000DS1400 1250kVA 3G FC 50Hz (MTU)Reference — 3239811 PG spec 18V2000DS1400 1250kVA 3G FC NOx 50Hz (MTU)Reference — MTU REACH SVHC 2021-03-17-EN final (MTU)Reference — MTU REACH SVHC 2025-09-19-EN final (MTU)

This page was generated from the 17 manufacturer documents above by automated extraction; every figure shown is copied from one of them. How the data is compiled.