Home›MTU›MTU 16V4000

MTU 16V4000 Generator Set

The MTU 16V4000 is a 45 kW (2350 kVA) Diesel standby generator set. It operates at 50 Hz.

45 kW
Standby
2
Document types

How to read your MTU serial & model number →

Typical fuel consumption for 45–50 kW Diesel generators →

Compare with other 45–50 kW Diesel generators →

Service parts for the 16V4000

Grouped by system, with how many of each the parts manual calls for.

Fuel system

1 required
0020922101Fuel filtersee priceAmazon

Prices captured from merchant listings; some links are affiliate links. Confirm against your serial number before ordering.

Specifications

FuelDiesel
Frequency50.0 Hz
Standby power45 kW
Standby kVA2350
Prime power45 kW

Maintenance & consumables

ItemSpecCapacityPart #Interval
Fuel filterFILTER FUEL SPIN ON 302 X 140 16V40000020922101 Amazon eBay

Recommended fluids

FluidGradeStandardAmbientCapacityNotes
FuelDiesel #2Recommended Fuel for diesel gensets (e.g. DS30, DS40, DS50, DS80, DS100, DS125, DS150, DS180, DS200, DS230, DS250, DS275, DS300, DS350, DS400, DS450, DS500)

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Voltage reconnection

VoltagePhaseConnectionLeadsNotes
208V312 LEAD WYEExample from MTU 4R0063 GS30
240V112 LEADExample from MTU 4R0063 GS30 SYSTEM RATINGS connection row
240V14 LEADExample from MTU 4R0063 GS30
240V312 LEAD DELTAExample from MTU 4R0063 GS30
380V312 LEAD WYEExample from MTU 4R0063 GS30
480V312 LEAD WYEExample from MTU 4R0063 GS30
600V34 LEAD WYE DOUBLE DELTAExample from MTU 4R0063 GS30

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Common questions

How many kW is the MTU 16V4000?

The MTU 16V4000 is rated 45 kW standby (2350.0 kVA).

Is the MTU 16V4000 diesel or gas?

The MTU 16V4000 runs on Diesel.

Which fuel filter part number does the MTU 16V4000 take?

The MTU 16V4000 uses fuel filter part number 0020922101.

Parts

14
Part #DescriptionQtySystem
0020922101FILTER FUEL SPIN ON 302 X 140 16V40004Fuel filter Amazon eBay
0289976148O-RING 150 X 5.2 16V40002Seal Amazon
5240140080GASKET 16V40001Gasket Amazon
5240980281HOSE 95.25 ID X 108 LG BLUE FIBERGLASS 16V40004Hose Amazon
X00026477TUBE ASM 212.116 OIL LINE 16V40001Hose Amazon
X00026478TUBE ASM 597.906 OIL LINE 16V40001Hose Amazon
X00026672TUBE ASM 231.277 OIL LINE 16V40001Hose Amazon
X00026673TUBE ASM 837.101 OIL LINE 16V40001Hose Amazon
X00027842FUEL LINE HIGH PRESS SINGLE WALL 16V40001Hose Amazon
X00040960TUBE FUEL LINE 484.534 16V40001Hose Amazon
X00040962TUBE FUEL LINE 922.675 16V40001Hose Amazon eBay
EX00026599EXCH HEAD ASM CYLINDER W/VALVES 16V400012Service part / kit Amazon
X00004066MANIFOLD EXHAUST 671.5 X 112.4 16V40004Service part / kit Amazon
X00026599HEAD ASM CYLINDER W/VALVES 16V4000; USE: EX00026599Service part / kit Amazon

Service, wear & replacement parts referenced for this model and its engine — confirm the exact part for your serial number. See the full parts catalog to search and cross-reference.

Available documents

Alternator spec — mtu4000-16v-ds2250-dccp (collicutt.com)Engine spec — 3234721 PG spec 8V12V16V20V4000GS 3A BG NOx500 50Hz (MTU)Spec sheet — 079a814e2dd4b7c93b2a1ea4562e4bb2 (MTU)Spec sheet — 16120795 PG NaturalGas S4000 brochure low (MTU)Spec sheet — 2160-Оптимизация-расхода-топлива-1 (MTU)Spec sheet — 231151 PG Spec 16V4000DS2000G04 2000kW 3D T2 SCAQMD 60Hz 50C (MTU)Spec sheet — 231152 PG Spec 16V4000DS2250G04 2250kW 3D T2 SCAQMD 60Hz 50C (MTU)Spec sheet — 231158 PG Spec 16V4000DS2000G04 1825kW 3F T2 SCAQMD 60Hz 50C (MTU)Spec sheet — 231159 PG Spec 16V4000DS2250G04 2045kW 3F T2 SCAQMD 60Hz 50C (MTU)Spec sheet — 231205 PG Spec 16V4000DS2000G04 2000kW 3D T2 SCAQMD 60Hz 45C (MTU)Spec sheet — 231206 PG Spec 16V4000DS2000G04 2000kW 3D FC 60Hz 45C (MTU)Spec sheet — 231207 PG Spec 16V4000DS2000G04 2000kW 3D FC 60Hz 50C (MTU)Spec sheet — 231208 PG Spec 16V4000DS2250G04 2250kW 3D T2 SCAQMD 60Hz 40C (MTU)Spec sheet — 231209 PG Spec 16V4000DS2250G04 2250kW 3D FC 60Hz 40C (MTU)Spec sheet — 231210 PG Spec 16V4000DS2250G04 2250kW 3D FC 60Hz 50C (MTU)Spec sheet — 231211 PG Spec 16V4000DS2500G04 2500kW 3D T2 SCAQMD 60Hz 45C (MTU)Spec sheet — 231212 PG Spec 16V4000DS2500G04 2500kW 3D FC 60Hz 45C (MTU)Spec sheet — 231232 PG Spec 16V4000DS2000G04 1825kW 3F T2 SCAQMD 60Hz 45C (MTU)Spec sheet — 231233 PG Spec 16V4000DS2000G04 1825kW 3F FC 60Hz 45C (MTU)Spec sheet — 231234 PG Spec 16V4000DS2000G04 1825kW 3F FC 60Hz 50C (MTU)Spec sheet — 231235 PG Spec 16V4000DS2250G04 2045kW 3F T2 SCAQMD 60Hz 40C (MTU)Spec sheet — 231236 PG Spec 16V4000DS2250G04 2045kW 3F FC 60Hz 40C (MTU)Spec sheet — 231237 PG Spec 16V4000DS2250G04 2045kW 3F FC 60Hz 50C (MTU)Spec sheet — 2360-NEA-Singapore-for-ORDE (MTU)Spec sheet — 3234731 PG spec 8V12V16V20V4000GS 3A NG NOx500 50Hz (MTU)Spec sheet — 3237261 PG spec 8V12V16V20V4000GS 3A BG NOx500 60Hz (MTU)Spec sheet — 3237271 PG spec 8V12V16V20V4000GS 3A BG 60Hz US (MTU)Spec sheet — 3237271 PG spec 8V12V16V20V4000GS 3A BG NOx1 60Hz (MTU)Spec sheet — 3237291 PG spec 8V12V16V20V4000GS 3A NG NOx500 60Hz (MTU)Spec sheet — 3237301 PG spec 8V12V16V20V4000 3A NG 60Hz US (MTU)Spec sheet — 3237301 PG spec 8V12V16V20V4000 3A NG NOx1 60Hz (MTU)Spec sheet — 3238491 PG spec 16V4000DS2250 2160kVA 3G FC 50Hz (MTU)Spec sheet — 3238501 PG spec 16V4000DS2500 2360kVA 3G FC 50Hz (MTU)Spec sheet — 3238651 PG spec 16V4000DS2250 2160kVA 3F NEA 50Hz (MTU)Spec sheet — 3238661 PG spec 16V4000DS2500 2360kVA 3F NEA 50Hz (MTU)Spec sheet — 3238741 PG spec 16V4000DS2500 2360kVA 3G NEA 50Hz (MTU)Spec sheet — 3238821 PG spec 16V4000DS2500 2360kVA 3E NOx 50Hz (MTU)Spec sheet — 3238971 PG spec 16V4000DS2250 2160kVA 3G NOx 50Hz (MTU)Spec sheet — EngineersGuidebook (MTU)Spec sheet — EngineersGuidebookUpdate102017 (MTU)Spec sheet — MTU-Engineers-Guidebook-2014 (MTU)Spec sheet — MTU-Onsite-Energy-Engineers-Guidebook (MTU)Spec sheet — MTU16V4000DS2000 1800kW Prime (MTU)Spec sheet — MTU16V4000DS2000 1825kW DCCP (MTU)Spec sheet — MTU16V4000DS2000 2000kW Standby (MTU)Spec sheet — MTU16V4000DS2250 2045kW Prime (MTU)Spec sheet — MTU16V4000DS2500 2500kW Standby (MTU)Spec sheet — MTU 16V4000 DS2000 2000kW Standby (MTU)Spec sheet — MTU 16V4000 DS2250kW Prime (MTU)Spec sheet — PSC 2ND POD - 28 - ssuggs@weilerengineering.org - KWRU FIlter CCC Replacement Replacement Generator Scope (Weiler Engineering)Spec sheet — PSC 2nd POD 28 - 800 kW Submittal (MTU)Spec sheet — mtu4000-16v-ds2000-dccp (MTU)Spec sheet — mtu4000-16v-ds2000-stand (MTU)Spec sheet — mtu4000-16v-ds2500-stand (MTU)Spec sheet — mtu4000-3110261 OE Flyer 4000Biogas 2 14 (MTU)Spec sheet — mtu4000-3237301 OE spec GN 4000 480V 60Hz US 2 14 (MTU)Operator's manual — tp6011 (Detroit Diesel)Reference — 16120643 PowerGeneration Solutionguide 1 2020 (MTU)Reference — 21162 Power of Co-generation TA (MTU)Reference — 2160-Оптимизация-качества-воздуха-1 (MTU)Reference — 21705 RR MicroGrid Design TA (MTU)Reference — BR4000 Gas Powered (MTU)Reference — MTU16V4000DS2250 2045kW DCCP (MTU)Reference — MTU16V4000DS2250 2250kW Standby (MTU)Reference — MTU 16V4000 DS2500 2500kW Prime (MTU)Reference — MTU Series-4000 50-Hz -400V (MTU)Reference — kr-en049q-eh5000ac-3 (Hitachi Construction Machinery)Reference — kr-en054p-eh4000ac-3 (Hitachi Construction Machinery)Reference — mtu4000-16v-ds2250-stand (MTU)Reference — p019392-2-ge-inf-00001 1 - informe mt degan i (Tractebel Engineering S.A)Parts manual — MTU4000-parts-list (Tripoly International Group)Parts manual — SA150206 Ser 4000 Fuel Booster ASM-1250-X2-3-3 (MTU)Parts manual — tp6217 (Kohler)Parts manual — tp6472Service manual — ABCWUA Add Info Rcvd 06292021 (MTU America)Service manual — Engineers Guidebook (MTU)Service manual — mtu-4000-service-manual (MTU)

This page was generated from the 77 manufacturer documents above by automated extraction; every figure shown is copied from one of them. How the data is compiled.