MTU 12V4000G14 Generator Set
The MTU 12V4000G14 is a 1352 kW (1600 kVA) diesel standby generator set powered by a MTU 12V4000G14F engine. It is available at 380 V, 400 V, 415 V and 11 V, three-phase-phase, 50 Hz and rated 2431 A. It holds about 260 L (68.7 gal) of oil and 160 L (42.3 gal) of coolant, with a maximum ambient rating of not specified °C. Starting uses 1 group-not specified battery rated 1420 CCA at 24 V. The set measures 4059×1810×2330 mm (159.8×71.3×91.7 in), weighs about 10654 kg (23488 lb) and produces not specified dBA at not specified m. An integrated tank holds not specified L (None gal), roughly not specified hours of runtime.
How to read your MTU serial & model number →
Compare with other 1350–1355 kW Diesel generators →
Specifications Fuel diesel Frequency 50.0 Hz Standby power 1352 kW Standby kVA 1600 Prime power 1352 kW Emissions NOx emission optimized Controller Basler controller Oil capacity 260.0 L Alternator Leroy-Somer LSA52.3 S5 Voltage options 380 V, 400 V, 415 V, 11 V Phase three-phase Rated current 2431 A Circuit breaker 2431 A Battery group not specified Battery cranking 1420 CCA Battery voltage 24 V Battery quantity 1 Coolant capacity 160 L Max ambient not specified °C Dimensions (L×W×H) 4059×1810×2330 mm Dry weight 10654 kg Tank runtime not specified hr
Engine MTU 12V4000G14F Oil capacity 260.0 L Coolant capacity 200.0 L Displacement 57.2 L Aspiration water charge air cooling Rated speed 1500 rpm
Common questions What is the power rating of the MTU 12V4000G14? The MTU 12V4000G14 is rated 1352 kW standby (1600.0 kVA).
What engine does the MTU 12V4000G14 use? The MTU 12V4000G14 is powered by the MTU 12V4000G14F engine.
What fuel does the MTU 12V4000G14 use? The MTU 12V4000G14 runs on diesel.
What is the oil capacity of the MTU 12V4000G14? The MTU 12V4000G14F engine in the MTU 12V4000G14 has an oil capacity of 260.0 liters.
What alternator does the MTU 12V4000G14 use? The MTU 12V4000G14 uses a Leroy-Somer LSA52.3 S5 alternator.
Fuel consumption Rating Load L/h gal/h Prime 50% 184.8 Prime 75% 272.0 75.2 Prime 100% 373.0 103.7 Standby 50% 200.2 1272.0 Standby 75% 274.6 1304.0 Standby 100% 342.2 1296.0
Available documents Reference — 1650kva-mtu-engines (MTU) Reference — 3237471 PG spec 12V4000DS1650 1600kVA 3B FC 50Hz (MTU) Reference — 3237481 PG spec 12V4000DS1750 1700kVA 3B FC 50Hz (MTU) Reference — 3237641 PG spec 12V4000DS1650 1600kVA 3B NOx 50Hz (MTU) Reference — 3237651 PG spec 12V4000DS1750 1700kVA 3B NOx 50Hz (MTU) Reference — 3237741 PG spec 12V4000DS1750 1700kVA 3B NEA 50Hz (MTU) Reference — 3238381 PG spec 12V4000DS1650 1600kVA 3F FC 50Hz (MTU) Reference — 3238541 PG spec 12V4000DS1650 1600kVA 3E NEA 50Hz (MTU) Reference — 3238551 PG spec 12V4000DS1750 1700kVA 3E NEA 50Hz (MTU) Reference — 3238781 PG spec 12V4000DS1650 1600kVA 3E NOx 50Hz (MTU) Reference — 3238791 PG spec 12V4000DS1750 1700kVA 3E NOx 50Hz (MTU) Reference — 3238861 PG spec 12V4000DS1650 1600kVA 3F NOx 50Hz (MTU) Reference — 3238871 PG spec 12V4000DS1750 1700kVA 3F NOx 50Hz (MTU) Reference — MTU REACH SVHC 2021-03-17-EN final (MTU)