Specifications
| Fuel | diesel |
|---|---|
| Frequency | 60.0 Hz |
| Standby power | 800 kW |
| Prime power | 730 kW |
| Emissions | EPA Tier 2 |
| Controller | Digital control panel |
| Oil capacity | 73.0 L |
| Alternator | Leroy-Somer LSA 49.3 L10 (4-pole) |
| Voltage options | 208 V, 240 V, 380 V, 480 V, 600 V |
| Phase | 3 |
| Power factor | 0.8 |
| Battery group | 4D |
| Battery cranking | 1050 CCA |
| Battery voltage | 24V V |
| Battery quantity | 2 |
| Coolant capacity | 109 L |
| Max ambient | 50 °C |
| Dimensions (L×W×H) | 4521×2135×2179 mm |
| Dry weight | 4774 kg |
| Sound level | 95.3 dBA @ 7 m |
Engine
| Oil capacity | 73.0 L |
|---|---|
| Coolant capacity | 65.0 L |
| Displacement | 22.44 L |
| Rated speed | 1800 rpm |
Common questions
What size generator is the MTU 12V1600 DS800?
The MTU 12V1600 DS800 is rated 800 kW standby.
What engine does the MTU 12V1600 DS800 use?
The MTU 12V1600 DS800 is powered by the MTU 12V1600G31S engine.
What fuel does the MTU 12V1600 DS800 use?
The MTU 12V1600 DS800 runs on diesel.
How much oil does the MTU 12V1600 DS800 take?
The MTU 12V1600G31S engine in the MTU 12V1600 DS800 has an oil capacity of 73.0 liters.
What is the cooling system capacity of the MTU 12V1600 DS800?
The MTU 12V1600 DS800 cooling system holds 109 liters (28.8 US gallons) for the radiator system including the engine, per the manufacturer specification sheet.
What is the prime power rating of the MTU 12V1600 DS800?
The MTU 12V1600 DS800 is rated 730 kW prime (912 kVA), against 800 kW standby.
How loud is the MTU 12V1600 DS800?
The MTU 12V1600 DS800 is rated at 95.3 dBA at 7 m, per the manufacturer specification sheet.
What is the dry weight of the MTU 12V1600 DS800?
The MTU 12V1600 DS800 has a dry weight of 4774 kg (10524 lb).
What voltages is the MTU 12V1600 DS800 available in?
The MTU 12V1600 DS800 is offered in 208 V, 240 V, 380 V, 480 V, 600 V, 3-phase.
What size battery does the MTU 12V1600 DS800 need?
The MTU 12V1600 DS800 uses 2 batteryies, 24V V each, 1050 CCA, group 4D, per the manufacturer specification sheet.
What alternator does the MTU 12V1600 DS800 use?
The MTU 12V1600 DS800 uses a Leroy-Somer LSA 49.3 L10 alternator. It has 4 poles.
Fuel consumption
| Rating | Load | L/h | gal/h |
|---|---|---|---|
| Prime | 50% | 104.1 | 27.5 |
| Prime | 75% | 139.7 | 36.9 |
| Prime | 100% | 186.7 | 49.3 |
Available documents
This page was generated from the 2 manufacturer documents above by automated extraction; every figure shown is copied from one of them. How the data is compiled.