Mecc Alte ECO 38 Generator Set
The Mecc Alte ECO 38 is a generator set.
Get a price quote on the Mecc Alte ECO 38New, used & surplus units from generator dealersSpecifications
| Ratings spec sheet not in our library yet — see the documents below. |
Filters & service parts (model family)
Compiled from this model's family documentation — may include parts for closely-related variants. Confirm the exact part for your serial number.
| Item | Spec | Capacity | Part # | Interval |
|---|---|---|---|---|
| Bolt | M10 Hexagonal nut | 6110601046 buy | ||
| Bolt | TE M10x50 Screw | 6110605417 buy | ||
| Fan | ECO 38 Fan | 6102217303 buy | ||
| Fan | ECO 40 Fan | 6102217355 buy | ||
| Key | ECO 38 A 16x10x60 key | 9911130565 buy | ||
| Key | ECO 40 A 20x12x70 key | 9911130595 buy | ||
| Service part / kit | Construction type B3B14 | B3B14 buy | ||
| Service part / kit | Construction form MD35 | MD35 buy | ||
| Service part / kit | Device | PD500 buy | ||
| Ring | ECO 38 D. 95 Seeger ring | 9911136245 buy | ||
| Ring | ECO 40 D. 120 Seeger ring | 9911136265 buy | ||
| Washer | Ø 10 serrated washer | 6110603250 buy | ||
| Washer | Ø 10 flat washer | 6110613053 buy | ||
| Air filter | find | 400 hr | ||
| Air filter cleaning | Every 2500 hours for ECO 38 and ECO 40 series | find | 2500 hr | |
| Battery | 8000 hr | |||
| Belt | find | |||
| Check correct fastening of pmg | Every 8000 hours / 1 year for ECO 38 and ECO 40 series | 8000 hr | ||
| Cleaning of windings | Every 20000 to 25000 hours for ECO series | 20000 hr | ||
| Coolant | ||||
| Coolant filter | find | 8000 hr | ||
| External and internal cleaning of the alternator | Every 15 days | 15 hr | ||
| Extraordinary maintenance | Every 4000 hours for ECO 38 and ECO 40 series | 4000 hr | ||
| Fuel filter | find | 4000 hr | ||
| General cleaning | Every 400 hours of use | 400 hr | ||
| Oil | SKF LGMT2 grease, or similar | 60.0 grams | 4000 hr | |
| Oil filter | find | 8000 hr | ||
| Other | ||||
| Spark plug | find | 8000 hr | ||
| Tightening torque check | Every 2500 hours | 2500 hr | ||
| Verification of correct alternator operation | Every 2500 hours | 2500 hr | ||
| Verification of winding state | Every 2500 hours | 2500 hr | ||
| Visual inspection | Every 2500 hours | 2500 hr | ||
| Winding state and diode bridge fastening check | Every 8000 hours / 1 year for ECO 38 and ECO 40 series | 8000 hr |