Specifications
| Fuel | Diesel |
|---|---|
| Frequency | 50.0 Hz |
| Standby power | 2400 kW |
| Standby kVA | 3000 |
| Prime power | 2182 kW |
| Emissions | EPA Tier 2 |
| Controller | M80-D APM403 APM802 |
| Alternator | KH06550T,KH09260T (4-pole, Class H insulation) |
| Voltage options | 400/230 V |
| Phase | 3 |
| Rated current | 4330 A |
| Power factor | 0.8 |
| Circuit breaker | 4330 A |
| Battery group | 24V |
| Battery voltage | 24 V |
| Battery quantity | 1 |
| Coolant capacity | 237 L |
| Max ambient | 105 °C |
| Dimensions (L×W×H) | 6950×3497×3552 mm |
| Dry weight | 23520 kg |
| Fuel tank | 0.0 L |
| Tank runtime | 0 hr |
Engine
| Coolant capacity | 237.0 L |
|---|---|
| Displacement | 82.74 L |
| Aspiration | Turbo |
| Rated speed | 1500 rpm |
Common questions
How many kW is the Kohler KD3000-E_RADIA?
The Kohler KD3000-E_RADIA is rated 2400 kW standby (3000.0 kVA).
What engine is in the Kohler KD3000-E_RADIA?
The Kohler KD3000-E_RADIA is powered by the Kohler KD83V16A-5AES engine.
What kind of fuel does the Kohler KD3000-E_RADIA run on?
The Kohler KD3000-E_RADIA runs on Diesel.
How much coolant does the Kohler KD3000-E_RADIA hold?
The Kohler KD3000-E_RADIA cooling system holds 237 liters (62.6 US gallons) for the radiator system including the engine, per the manufacturer specification sheet.
What is the prime power rating of the Kohler KD3000-E_RADIA?
The Kohler KD3000-E_RADIA is rated 2182 kW prime (2727 kVA), against 2400 kW standby.
How much does the Kohler KD3000-E_RADIA weigh?
The Kohler KD3000-E_RADIA has a dry weight of 23520 kg (51852 lb).
What voltage does the Kohler KD3000-E_RADIA produce?
The Kohler KD3000-E_RADIA is offered in 400/230 V, 3-phase.
What size battery does the Kohler KD3000-E_RADIA need?
The Kohler KD3000-E_RADIA uses 1 battery, 24 V each, group 24V, per the manufacturer specification sheet.
What alternator does the Kohler KD3000-E_RADIA use?
The Kohler KD3000-E_RADIA uses a KH06550T,KH09260T alternator. It has 4 poles. Insulation class H.
Fuel consumption
| Rating | Load | L/h | gal/h |
|---|---|---|---|
| Prime | 25% | 187.5 | 69.3 |
| Prime | 50% | 341.7 | 125.5 |
| Prime | 75% | 510.2 | 187.5 |
| Prime | 100% | 689.4 | 248.5 |
| Standby | 25% | 187.5 | 69.3 |
| Standby | 50% | 341.7 | 125.5 |
| Standby | 75% | 510.2 | 187.5 |
| Standby | 100% | 689.4 | 248.5 |
Available documents
This page was generated from the 1 manufacturer document above by automated extraction; every figure shown is copied from one of them. How the data is compiled.