Home›Hipower›Hipower HRNG 430 T6

Hipower HRNG 430 T6 Generator Set

The Hipower HRNG 430 T6 is a 193.4 kW (242 kVA) Gaseous standby generator set powered by a Power Solutions International 21.9L engine. It is available at 120/240 V, 120/208 V, 277/480 V and 347/600 V, single-phase, 60 Hz and rated 1600 A. It holds about 40 L (10.6 gal) of oil and 228 L (60.2 gal) of coolant, with a maximum ambient rating of 1000 °C. Starting uses 1 group-200 battery rated 1000 CCA at 24 V. The set measures 4520×2110×2360 mm (178.0×83.1×92.9 in), weighs about 5358 kg (11812 lb) and produces 77 dBA at 7 m. An integrated tank holds 228 L (60.2 gal), roughly 1000 hours of runtime. The same 21.9L engine also powers generator sets from Power Solutions International.

193 kW
Standby
21.9 L
Displacement
40.0 L
Oil capacity
1
Document types

Specifications

FuelGaseous
Frequency60.0 Hz
Standby power193 kW
Standby kVA242
EmissionsEPA certified
ControllerDigital control panel
Oil capacity40.0 L
AlternatorStamford/AvK HCI 434 E N.G. (4-pole, Class Class H insulation)
Voltage options120/240 V, 120/208 V, 277/480 V, 347/600 V
Phase1 or 3
Rated current1600 A
Power factor0.8
Circuit breaker1600 A
Battery group200 AH
Battery cranking1000 CCA
Battery voltage24 V
Battery quantity1
Coolant capacity228 L
Max ambient1000 °C
Dimensions (L×W×H)4520×2110×2360 mm
Dry weight5358 kg
Sound level77.0 dBA @ 7 m
Fuel tank228.0 L
Tank runtime1000 hr

Engine

Power Solutions International 21.9L
Oil capacity40.0 L
Coolant capacity228.0 L
Displacement21.9 L
AspirationTurbo Charge Air Cooled
Rated speed1800 rpm

Same engine, other brands

1 brand

The Power Solutions International 21.9L in this set also powers 1 generator set sold under 1 other brand. Service parts and maintenance intervals for the engine are shared; enclosure, alternator, controller and ratings are not.

BrandModels
Power Solutions InternationalPSI 21.9-liter

Maintenance & consumables

for the Power Solutions International 21.9L
ItemSpecCapacityPart #Interval
Air filterDry, replacable cartridge×1—
Fuel filterN/A—
Oil filterReplaceable Spin-On×1—
Battery200 AH—
BeltN/A—
Spark plugN/A—

Common questions

What size generator is the Hipower HRNG 430 T6?

The Hipower HRNG 430 T6 is rated 193 kW standby (242.0 kVA).

What engine does the Hipower HRNG 430 T6 use?

The Hipower HRNG 430 T6 is powered by the Power Solutions International 21.9L engine.

What fuel does the Hipower HRNG 430 T6 use?

The Hipower HRNG 430 T6 runs on Gaseous.

What's the oil capacity on a Hipower HRNG 430 T6?

The Power Solutions International 21.9L engine in the Hipower HRNG 430 T6 has an oil capacity of 40.0 liters.

What is the coolant capacity of the Hipower HRNG 430 T6?

The Hipower HRNG 430 T6 cooling system holds 228 liters (60.2 US gallons) for the radiator system including the engine, per the manufacturer specification sheet.

What is the sound level of the Hipower HRNG 430 T6?

The Hipower HRNG 430 T6 is rated at 77.0 dBA at 7 m, per the manufacturer specification sheet.

How much does the Hipower HRNG 430 T6 weigh?

The Hipower HRNG 430 T6 has a dry weight of 5358 kg (11812 lb).

What size fuel tank does the Hipower HRNG 430 T6 have?

The Hipower HRNG 430 T6 has a 228 liter (60 US gallon) fuel tank, giving about 1000 hours of runtime.

What voltage does the Hipower HRNG 430 T6 produce?

The Hipower HRNG 430 T6 is offered in 120/240 V, 120/208 V, 277/480 V, 347/600 V, 1 or 3-phase.

How many cold cranking amps does the Hipower HRNG 430 T6 require?

The Hipower HRNG 430 T6 uses 1 battery, 24 V each, 1000 CCA, group 200 AH, per the manufacturer specification sheet.

What alternator comes on the Hipower HRNG 430 T6?

The Hipower HRNG 430 T6 uses a Stamford/AvK HCI 434 E N.G. alternator. It has 4 poles. Insulation class Class H.

Fuel consumption

RatingLoadL/hgal/h
Prime100%476.96126.0

Available documents

Spec sheet — HIPOWER HRNG-430-T6 (Hipower)Spec sheet — file 168 ds hrng 430 t6 (Hipower)

This page was generated from the 2 manufacturer documents above by automated extraction; every figure shown is copied from one of them. How the data is compiled.