Specifications
| Fuel | Diesel |
|---|---|
| Frequency | 60.0 Hz |
| Standby power | 925 kW |
| Standby kVA | 1012 |
| Prime power | 835 kW |
| Emissions | not stated |
| Controller | not stated |
| Oil capacity | 16.0 L |
| Alternator | QST30G3 |
| Voltage options | 480 V, 240 V |
| Phase | 3 |
| Rated current | 809 A |
| Power factor | 0.8 |
| Circuit breaker | 701 A |
| Battery group | 170X170 |
| Battery voltage | 12 V |
| Battery quantity | 6 |
| Coolant capacity | 2052 L |
| Max ambient | 40 °C |
| Dimensions (L×W×H) | 1879×4266×2052 mm |
| Dry weight | 6387 kg |
| Sound level | 70.0 dBA @ 7 m |
| Fuel tank | 1879.0 L |
| Tank runtime | 2400 hr |
Engine
| Oil capacity | 1007.0 L |
|---|---|
| Coolant capacity | 4266.0 L |
| Displacement | 30.0 L |
| Aspiration | Turbocharged |
| Rated speed | 1800 rpm |
Common questions
What is the power rating of the Everdigm EDG-900C?
The Everdigm EDG-900C is rated 925 kW standby (1012.0 kVA).
Which engine powers the Everdigm EDG-900C?
The Everdigm EDG-900C is powered by the MTU QST30G3 engine.
What fuel does the Everdigm EDG-900C use?
The Everdigm EDG-900C runs on Diesel.
What is the oil capacity of the Everdigm EDG-900C?
The MTU QST30G3 engine in the Everdigm EDG-900C has an oil capacity of 1007.0 liters.
How much coolant does the Everdigm EDG-900C hold?
The Everdigm EDG-900C cooling system holds 2052 liters (542.1 US gallons) for the radiator system including the engine, per the manufacturer specification sheet.
What is the prime power rating of the Everdigm EDG-900C?
The Everdigm EDG-900C is rated 835 kW prime (920 kVA), against 925 kW standby.
How loud is the Everdigm EDG-900C?
The Everdigm EDG-900C is rated at 70.0 dBA at 7 m, per the manufacturer specification sheet.
How much does the Everdigm EDG-900C weigh?
The Everdigm EDG-900C has a dry weight of 6387 kg (14080 lb).
What size fuel tank does the Everdigm EDG-900C have?
The Everdigm EDG-900C has a 1879 liter (496 US gallon) fuel tank, giving about 2400 hours of runtime.
What voltages is the Everdigm EDG-900C available in?
The Everdigm EDG-900C is offered in 480 V, 240 V, 3-phase.
What size battery does the Everdigm EDG-900C need?
The Everdigm EDG-900C uses 6 batteryies, 12 V each, group 170X170, per the manufacturer specification sheet.
What alternator does the Everdigm EDG-900C use?
The Everdigm EDG-900C uses a QST30G3 alternator.
Fuel consumption
| Rating | Load | L/h | gal/h |
|---|---|---|---|
| Prime | 50% | 73.0 | 122.0 |
| Prime | 60% | 73.0 | 122.0 |
| Standby | 50% | 73.0 | 122.0 |
| Standby | 60% | 73.0 | 122.0 |
Available documents