Specifications
| Fuel | Diesel |
|---|---|
| Frequency | 60.0 Hz |
| Standby power | 1012 kW |
| Standby kVA | 1112 |
| Prime power | 920 kW |
| Emissions | not stated |
| Controller | not stated |
| Oil capacity | 16.0 L |
| Alternator | QST30G4 |
| Voltage options | 480 V, 240 V |
| Phase | 3 |
| Rated current | 809 A |
| Power factor | 0.8 |
| Circuit breaker | 701 A |
| Battery group | 170X170 |
| Battery voltage | 12 V |
| Battery quantity | 6 |
| Coolant capacity | 2052 L |
| Max ambient | 40 °C |
| Dimensions (L×W×H) | 1879×4266×2052 mm |
| Dry weight | 6387 kg |
| Sound level | 70.0 dBA @ 7 m |
| Fuel tank | 1879.0 L |
| Tank runtime | 2400 hr |
Engine
| Oil capacity | 1112.0 L |
|---|---|
| Coolant capacity | 4266.0 L |
| Displacement | 30.0 L |
| Aspiration | Turbocharged |
| Rated speed | 1800 rpm |
Common questions
What is the power rating of the Everdigm EDG-1000C?
The Everdigm EDG-1000C is rated 1012 kW standby (1112.0 kVA).
Which engine powers the Everdigm EDG-1000C?
The Everdigm EDG-1000C is powered by the MTU QST30G4 engine.
What kind of fuel does the Everdigm EDG-1000C run on?
The Everdigm EDG-1000C runs on Diesel.
How much oil does the Everdigm EDG-1000C take?
The MTU QST30G4 engine in the Everdigm EDG-1000C has an oil capacity of 1112.0 liters.
What is the cooling system capacity of the Everdigm EDG-1000C?
The Everdigm EDG-1000C cooling system holds 2052 liters (542.1 US gallons) for the radiator system including the engine, per the manufacturer specification sheet.
What is the continuous rating of the Everdigm EDG-1000C?
The Everdigm EDG-1000C is rated 920 kW prime (1005 kVA), against 1012 kW standby.
How loud is the Everdigm EDG-1000C?
The Everdigm EDG-1000C is rated at 70.0 dBA at 7 m, per the manufacturer specification sheet.
How much does the Everdigm EDG-1000C weigh?
The Everdigm EDG-1000C has a dry weight of 6387 kg (14080 lb).
What size fuel tank does the Everdigm EDG-1000C have?
The Everdigm EDG-1000C has a 1879 liter (496 US gallon) fuel tank, giving about 2400 hours of runtime.
What voltage does the Everdigm EDG-1000C produce?
The Everdigm EDG-1000C is offered in 480 V, 240 V, 3-phase.
How many cold cranking amps does the Everdigm EDG-1000C require?
The Everdigm EDG-1000C uses 6 batteryies, 12 V each, group 170X170, per the manufacturer specification sheet.
What alternator comes on the Everdigm EDG-1000C?
The Everdigm EDG-1000C uses a QST30G4 alternator.
Fuel consumption
| Rating | Load | L/h | gal/h |
|---|---|---|---|
| Prime | 50% | 73.0 | 122.0 |
| Prime | 60% | 73.0 | 122.0 |
| Standby | 50% | 73.0 | 122.0 |
| Standby | 60% | 73.0 | 122.0 |
Available documents