Home›Denyo›Denyo 220SP~ 300SP GLASS

Denyo 220SP~ 300SP GLASS Generator Set

The Denyo 220SP~ 300SP GLASS is a 160 kW (200 kVA) Diesel standby generator set powered by a Komatsu S6D125£-2-A engine. It is available at 200/220 V, 400/440 V, 380 V and 415 V, 3-phase and rated 571 A. It holds about 40 L (10.6 gal) of oil and 34 L (9.0 gal) of coolant, with a maximum ambient rating of 700 °C. Starting uses 150 group-12 battery at 12 V. The set measures 3650×1300×1750 mm (143.7×51.2×68.9 in) and weighs about 3670 kg (8091 lb). An integrated tank holds 380 L (100.4 gal).

160 kW
Standby
11.04 L
Displacement
40.0 L
Oil capacity
1
Document types

Typical fuel consumption for 160–165 kW Diesel generators →

Compare with other 160–165 kW Diesel generators →

Specifications

FuelDiesel
Standby power160 kW
Standby kVA200
Oil capacity40.0 L
AlternatorKomatsu SA6D125E-2-A
Voltage options200/220 V, 400/440 V, 380 V, 415 V
PhaseThree-phase (four wire)
Rated current571/577 A
Power factor0. 8 (lagging )
Circuit breaker179/787 A
Battery group12V - (DOMESTIC STANDERD)
Battery voltage12V V
Battery quantity150AhxX 2
Coolant capacity34.0 L
Max ambient700~ 800 °C
Dimensions (L×W×H)3650×1300×1750 mm
Dry weight3670 kg
Fuel tank380.0 L

Engine

Komatsu S6D125£-2-A
Oil capacity40.0 L
Coolant capacity34.0 L
Displacement11.04 L
Aspirationwatercooled dies! engine direct injection with lurbocharger
Rated speed1500 rpm

Common questions

How many kW is the Denyo 220SP~ 300SP GLASS?

The Denyo 220SP~ 300SP GLASS is rated 160 kW standby (200.0 kVA).

What engine does the Denyo 220SP~ 300SP GLASS use?

The Denyo 220SP~ 300SP GLASS is powered by the Komatsu S6D125£-2-A engine.

Is the Denyo 220SP~ 300SP GLASS diesel or gas?

The Denyo 220SP~ 300SP GLASS runs on Diesel.

What is the oil capacity of the Denyo 220SP~ 300SP GLASS?

The Komatsu S6D125£-2-A engine in the Denyo 220SP~ 300SP GLASS has an oil capacity of 40.0 liters.

What is the coolant capacity of the Denyo 220SP~ 300SP GLASS?

The Denyo 220SP~ 300SP GLASS cooling system holds 34 liters (9.0 US gallons) for the radiator system including the engine, per the manufacturer specification sheet.

How much does the Denyo 220SP~ 300SP GLASS weigh?

The Denyo 220SP~ 300SP GLASS has a dry weight of 3670 kg (8090 lb).

What size fuel tank does the Denyo 220SP~ 300SP GLASS have?

The Denyo 220SP~ 300SP GLASS has a 380 liter (100 US gallon) fuel tank.

What voltage does the Denyo 220SP~ 300SP GLASS produce?

The Denyo 220SP~ 300SP GLASS is offered in 200/220 V, 400/440 V, 380 V, 415 V, Three-phase (four wire)-phase.

What size battery does the Denyo 220SP~ 300SP GLASS need?

The Denyo 220SP~ 300SP GLASS uses 150AhxX 2 batteryies, 12V V each, group 12V - (DOMESTIC STANDERD), per the manufacturer specification sheet.

What alternator does the Denyo 220SP~ 300SP GLASS use?

The Denyo 220SP~ 300SP GLASS uses a Komatsu SA6D125E-2-A alternator.

Troubleshooting

6

Symptoms & remedies

SymptomCauseRemedy
Cell motor will not runRepair
Engine will not start upTurn ON
Cell motor runsSpeed will not rise
Engine starts upSpeed rises
Voltmeter will not operateRated voltage will not be reached
Voltage goes too highApplied load causes large voltage drop

Fault codes and symptom→remedy steps extracted from this model’s service/owner documentation; verify against the official manual before servicing. Full Denyo 220SP~ 300SP GLASS troubleshooting guide (9 entries) →

Fuel consumption

RatingLoadL/hgal/h
Prime41%41.097.0
Standby42%42.097.0

Available documents

Owner's manual — DCA-220SPK3, DCA-300SPK3 (Denyo)

This page was generated from the 1 manufacturer document above by automated extraction; every figure shown is copied from one of them. How the data is compiled.