Home›Cummins/Onan›Cummins/Onan QG 7000

Cummins/Onan QG 7000 Generator Set

The Cummins/Onan QG 7000 is a gasoline generator set powered by a Cummins/Onan OHV EH65V engine. It is available at 120 V, single-phase, 60 Hz and rated 58.3 A. It holds about 1.9 L (0.5 gal) of oil, with a maximum ambient rating of 49 °C. The set measures 853.44×563.88×424.18 mm (33.6×22.2×16.7 in), weighs about 131.54 kg (290 lb) and produces 70 dBA at 3 m.

0.653 L
Displacement
1.9 L
Oil capacity
3
Document types

How to read your Cummins/Onan serial & model number →

Specifications

Fuelgasoline
Frequency60.0 Hz
EmissionsCARB Tier 3 / EPA Phase 3
ControllerIntegral box
Oil capacity1.9 L
Alternatorrevolving field AC, 2-pole self-excited (2-pole, Class meets ANSI/RVIA EGS-1 and CSA Electrical Bulletin 946 insulation)
Voltage options120 V
Phase1
Rated current58.3 A
Circuit breaker30 A
Max ambient49 °C
Dimensions (L×W×H)853×563×424 mm
Dry weight131 kg
Sound level70.0 dBA @ 3 m

Engine

Cummins/Onan OHV EH65V
Oil capacity1.9 L
Coolant capacity0.0 L
Displacement0.653 L
Aspirationnaturally aspirated
Rated speed2880 rpm

Maintenance & consumables

for the Cummins/Onan OHV EH65V
ItemSpecCapacityPart #Interval
Air filterreplaceable dry element air cleaner—
Fuel filterlong-life fuel filter—
Oil filterspin-on, full-flow lube oil filter—
BatteryBattery charging - 5 A—
Belt2 in exhaust tubes, straight with flanged end—
CoolantCentrifugal blower, generator set-mounted for high effectiveness, pressurized system, vertical flow—
Oilspin-on, full-flow lube oil filter2.0 L—
Spark plugElectronic magneto type with resistor plugs—

Service specifications

9
TypeItemValueUnitCondition
OtherEC-AGS+ gateway dimensions120 x 108 x 38mm
OtherTemperature sensor dimensions51 x 70 x 17mm
ResistanceGateway harness continuity maximum resistance10Ohmsrepair or replace harness if greater
TemperatureEC-AGS+ gateway operating temperature range-40 to 70°C
TemperatureTemperature sensor operating temperature range-40 to 85°C
VoltageEC-AGS+ nominal operating voltage12Vnominal
VoltageEC-AGS+ operating voltage range8 to 16VDC
VoltageMinimum house battery voltage for AGS use9VAGS not allowed below this
VoltageTemperature sensor battery replacement threshold2.5Vreplace when below

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Recommended fluids

FluidGradeStandardAmbientCapacityNotes
Engine oilFull pressure positive displacement pump-29°C to 49°C2.0 qtGasoline models: -20°F to 120°F (-29°C to 49°C); LP models: 0°F to 120°F (-18°C to 49°C)

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Procedures

6
Installation and Setup Test diagnostic
  1. Verify generator set operation using the Start/Stop switch located on the generator set.
  2. Verify manual start/stop of the generator set from the app dashboard using the START and PRIME/STOP buttons.
  3. Check operation of the temperature sensors with Auto mode and Air Conditioning Sense enabled.
  4. Verify the generator set starts automatically when the settings are met.
  5. Verify the accelerometer by driving the vehicle at 10 mph and checking that AGS is automatically disabled.
  6. Verify delayed shutdown: enable AGS, allow the generator set to start, disable AGS, confirm shutdown in 10 minutes.
Connect Components (EC-AGS+ Gateway) installation

⚠ Accidental starting of the generator set can cause severe personal injury or death. Disconnect the starting (battery) cables before performing service.

⚠ Always disconnect a battery charger from its AC source before disconnecting the battery cables.

⚠ Seal all holes to prevent the entrance of exhaust gases into the vehicle interior.

  1. Plug the 12-pin connector from the harness to the EC-AGS+ gateway.
  2. Route the other end of the harness from the gateway to the Y-harness.
  3. For gas generator sets, plug the 8-pin EC-AGS+ harness connector into either lead of the Y-harness.
  4. For diesel generator sets, plug the 10-pin EC-AGS+ harness connector into the longer lead of the Y-harness.
  5. Connect the main lead of the Y-harness to the generator set.
  6. Connect the remaining Y-harness connector to the remote start/stop switch harness.
  7. Route the red wire lead to the positive terminal of the generator set starting battery and extend as necessary using butt connectors.
  8. Provide circuit protection by installing a 5 Amp fuse in the red wire lead.
  9. Locate the common ground location on the vehicle and route the black wire lead to the common ground.
  10. Route the grey wire lead to the engine battery positive terminal (optional connection).
  11. Insert battery ring terminal to the wires and connect the wires.
  12. Use cable ties at not less than 0.5 m (20 in) intervals to keep the wire bundle neat.
Connect Temperature Sensor(s) installation

Tools: Small flathead screwdriver

  1. Remove the lid from the sensor using a small flathead screwdriver.
  2. Remove the plastic battery tab from the sensor to enable the battery to provide power to the sensor.
  3. Place the lid back on the sensor.
Mount Components installation

⚠ High ambient temperature can cause damage to the EC-AGS+ gateway.

  1. Do not install the EC-AGS+ gateway directly inside the generator set compartment.
  2. Mount the EC-AGS+ gateway in a suitable, easily accessible location.
  3. Drill holes for the fastening screws and mount the EC-AGS+ gateway using mounting screws.
  4. Mount the temperature sensor(s) near an A/C thermostat (one per zone, 3 maximum).
  5. Drill 2 holes for screws and mount the sensor.
Temperature Sensor Battery Replacement maintenance

⚠ Pushing on the cover too hard can damage or break it.

Tools: Small flathead screwdriver

  1. Make sure the generator set is not set to start in Auto mode.
  2. Remove the top cover of the temperature sensor using a small flathead screwdriver.
  3. Slide the battery out of the battery holder and remove the battery.
  4. Slide the new battery into the battery holder and replace the cover.
Configure System Using App (Getting Started) operation

⚠ For first time set up or after factory reset, the vehicle must be kept stationary for at least 30 seconds to allow the gateway accelerometer to be configured properly.

  1. Download the EC-AGS+ app from the AppStore for iOS or Play Store for Android.
  2. Reconnect the generator set negative battery cable to power on the EC-AGS+ gateway.
  3. Verify that the EC-AGS+ gateway is powered by observing the LED blinking every 5 seconds.
  4. Turn on Bluetooth on the device containing the app.
  5. Select the EC-AGS+ App and select Start.
  6. Connect the gateway to the app via Discover EC-AGS+, Scan QR code, or gateway password.
  7. Read the End User License Agreement to the end and select Agree.
  8. Create a new password and select Assign Password.
  9. Select the generator set model and type; enter the Start Hours from the hour meter if available.
  10. Select Proceed to Dashboard.

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Common questions

What engine does the Cummins/Onan QG 7000 use?

The Cummins/Onan QG 7000 is powered by the Cummins/Onan OHV EH65V engine.

Is the Cummins/Onan QG 7000 diesel or gas?

The Cummins/Onan QG 7000 runs on gasoline.

What's the oil capacity on a Cummins/Onan QG 7000?

The Cummins/Onan OHV EH65V engine in the Cummins/Onan QG 7000 has an oil capacity of 1.9 liters.

What is the sound level of the Cummins/Onan QG 7000?

The Cummins/Onan QG 7000 is rated at 70.0 dBA at 3 m, per the manufacturer specification sheet.

How much does the Cummins/Onan QG 7000 weigh?

The Cummins/Onan QG 7000 has a dry weight of 131 kg (289 lb).

What voltage does the Cummins/Onan QG 7000 produce?

The Cummins/Onan QG 7000 is offered in 120 V, 1-phase.

What alternator comes on the Cummins/Onan QG 7000?

The Cummins/Onan QG 7000 uses a revolving field AC, 2-pole self-excited alternator. It has 2 poles. Insulation class meets ANSI/RVIA EGS-1 and CSA Electrical Bulletin 946.

Parts

13
Part #DescriptionQtySystem
148-1161LPG vapor fuel conversion kit1Service part / kit eBay
155-2424Exhaust tube, straight with flanged end (7 in)1Service part / kit eBay $94.33
155-2610Exhaust tube, straight with flanged end (3 in)1Service part / kit eBay
155-2610-01Exhaust tube, straight with flanged end (12.5 in)1Service part / kit eBay
155-3481-01Tailpipe kit (22 in)1Service part / kit eBay $100.36
155-3481-02Tailpipe kit (26 in)1Service part / kit eBay $77.99
300-5331Remote start/stop rocker switch1Service part / kit eBay $148.60
300-5332Remote control with start/stop switch and running time meter1Service part / kit eBay $145.00
300-5333Remote control w/start/stop switch and DC voltmeter1Service part / kit eBay $240.02
338-3489-01Remote control plug and wire harness (10 ft)1Service part / kit eBay $65.25
338-3489-02Remote control plug and wire harness (30 ft)1Service part / kit eBay $65.00
405-6699Underfloor mounting kit1Service part / kit eBay
539-2057Installation template1Service part / kit eBay

Service, wear & replacement parts referenced for this model and its engine — confirm the exact part for your serial number. See the full parts catalog to search and cross-reference.

Fuel consumption

RatingLoadL/hgal/h
50%2.270.6
100%3.410.9
Full load100%4.61.2
Half load50%2.80.7
No load1.60.4

Available documents

Spec sheet (Cummins/Onan)Reference — 0043135 (Cummins/Onan)Reference — 0059498 (Cummins/Onan)Reference — F-1823-ENOwner's manual — F-1123-EN (Cummins/Onan)Owner's manual — Onan-EC-AGS Manual (Cummins/Onan)

This page was generated from the 6 manufacturer documents above by automated extraction; every figure shown is copied from one of them. How the data is compiled.