Specifications
| Fuel | No.2 Diesel |
|---|---|
| Frequency | 50.0 Hz |
| Standby power | 25 kW |
| Standby kVA | 31 |
| Prime power | 25 kW |
| Oil capacity | 9.0 L |
| Voltage options | 344 V |
| Phase | 3 |
| Power factor | 0.8 |
| Battery group | 12 |
| Battery cranking | 500 CCA |
| Battery voltage | 12 V |
| Battery quantity | 1 |
| Coolant capacity | 3.3 L |
| Max ambient | [30, 40] °C |
| Fuel tank | 91.0 L |
Maintenance & consumables
for the Cummins/Onan 6A3.4| Item | Spec | Capacity | Part # | Interval | |
|---|---|---|---|---|---|
| Air filter | Check for oil, fuel, cooling and exhaust system leaks. Check exhaust system audibly and visually. | — | find | ||
| Fuel filter | FSl496 | PartsGeek | |||
| Oil filter | — | 500 hr | find | ||
| Belt | 60 pounds (267 N) | — | 3 hr | find | |
| Coolant | — | ||||
| Coolant filter | — | find | |||
| Oil | — |
Common questions
What is the power rating of the Cummins/Onan MDL6?
The Cummins/Onan MDL6 is rated 25 kW standby (31.25 kVA).
What engine does the Cummins/Onan MDL6 use?
The Cummins/Onan MDL6 is powered by the Cummins/Onan 6A3.4 engine.
What fuel does the Cummins/Onan MDL6 use?
The Cummins/Onan MDL6 runs on No.2 Diesel.
Troubleshooting
6Symptoms & remedies
| Symptom | Cause | Remedy |
|---|---|---|
| Engine does not crank. | Battery dead. | Check battery per Checkout [A] and recharge or replace. Check battery charger operation per jumper battery cable B+ connection to 81 starter solenoid terminal. Does engine crank? If no, check battery cables for clean tight connections and motor-if bad, repair or replace. (ref. Checkout [B]). Check B1 starter solenoid With S11 in Start position, is battery voltage present between K11 terminal S and ground? If not, check B+_/wiring between K11 and B1 solenoid terminal. Replace if bad. If K11 does not energize, test per Checkout [D] and replace if bad. Is battery voltage present at B1 solenoid terminal with S11 in Start position. Check breakers CB11, CB13, or fuse F1. Check S11 and replace if bad. Check B+/wiring to S11 start terminal and K11 -S terminal. |
| Engine cranks but does not start. | Heater circuit operating improperly or incorrect fuel. | Check heater solenoid K13 per Checkout [HI. Check diodes CR2 and CR3, wiring, heaters, and resistors START. Check fuel supply system: fuel tank level, shutoff valves, fuel lines and connections, fuel filters, transfer pump and injection blue-white, and fuel flow steady from fuel return line. Check fault reset breaker. Check B+ circuit through K11-I to Engine monitor board terminal All-1, All-CB12 Line, All-SW B+, to K1. Does K1 fuel solenoid energize when S l l is in Start position? Incorrect fuel? See Operator’s Manual recommendations. |
| Engine starts but stops after running several seconds. | A fault condition indicated by fault breaker CB12 on control panel or DC control breaker trips when the generator set is started. | Check for a possible fault condition. If none, check fault monitors S1 through S5 and fault breaker CB12 for improper wiring. Check all B+ wiring for shorts to ground. |
| NO AC OUTPUT VOLTAGE AT RATED ENGINE RPM | Check lead continuity between AC terminals on A1 and terminals 2 and 3 on VR21 per TEST [Ml. Replace defective field breaker. Remove one lead from breaker and check continuity with ohmmeter. Is breaker open? Is control panel field breaker CB21 on? | |
| Voltage is unstable, high or low | Push to reset breaker. Does generator AC output voltage build up? If no, flash exciter field per TEST [D]. Does generator output voltage build up? | |
| Residual voltage across terminals 2 and 3 of VR21 is less than 5 to 10 VAC | Disconnect stator leads from leads 1 and 2 from AC across the leads. Is residual voltage 4 and 5,5 VDC or more now? Check reactor CMR21 and transformer T21 per TESTS (B) and (E). For shorts per TEST [MI. |
Fault codes and symptom→remedy steps extracted from this model’s service/owner documentation; verify against the official manual before servicing.
Parts
19| Part # | Description | Qty | System | |
|---|---|---|---|---|
| 102-3456 | Drip Pan | 1 | Drip pan | PartsGeek |
| 102-7890 | Hold Down Clamps or Through Bolts (1/2 inch [13 mm]) | 2 | Hold down clamps or through bolts | PartsGeek |
| 122-0712 | Oil Filter MDL4/6 ESN 5312 5968 and Up | Oil filter | PartsGeek kuduparts $11.00 | |
| 149-1802 | Fuel Filter Element MDL6 | Fuel filter | PartsGeek | |
| 149-2289 | Glow Plug MDL3, MDL4, MDL6 (12 Volt) | Glow plug | PartsGeek | |
| 333-0220 | Glow Plug MDL3, MDL4, MDL6 (12 Volt) | Glow plug | PartsGeek | |
| 511-0147-14 | Water Pump Belt MDL3, MDL4, MDL6 | Water pump belt | PartsGeek | |
| CB12 | Control breaker | Breaker | PartsGeek | |
| FSl245 | Battery | 1 | Battery | PartsGeek |
| FSl496 | Fuel Filter | 1 | Fuel filter | PartsGeek |
| yl67B-2 | Fuel Line Tee | Fuel filter | PartsGeek | |
| 934-0500 | 1 | Service part / kit | PartsGeek | |
| 934-0602 | 1 | Service part / kit | PartsGeek | |
| 960-0135 | Service part / kit | PartsGeek | ||
| ES-1494-1 | DRIVE DISK | Service part / kit | PartsGeek | |
| ES-1512-1 | REGULATOR BOARD ASSEMBLY | Service part / kit | PartsGeek | |
| ES1491 | ROTOR DIODE ASSEMBLIES H1 THROUGH H4 | Service part / kit | PartsGeek | |
| SG13753r | AC Control Breakers | Service part / kit | PartsGeek | |
| sa377 | Resonator | 1 | Service part / kit | PartsGeek |
Service, wear & replacement parts referenced for this model and its engine — confirm the exact part for your serial number. See the full parts catalog to search and cross-reference.
Fuel consumption
| Rating | Load | L/h | gal/h |
|---|---|---|---|
| Prime | |||
| Prime | 50% | 3.0 | |
| Prime | 100% | 6.1 | |
| Standby |