Specifications
| Fuel | regular-grade gasoline |
|---|---|
| Frequency | 60.0 Hz |
| Standby power | 1 kW |
| Standby kVA | 1 |
| Oil capacity | 0.55 L |
| Voltage options | 120 V |
| Phase | single-phase |
| Rated current | 10 A |
| Power factor | 100 |
| Battery voltage | 12 V |
| Battery quantity | 1 |
| Dimensions (L×W×H) | 489×366×443 mm |
| Dry weight | 33 kg |
| Fuel tank | 8.0 L |
Engine
| Oil capacity | 0.55 L |
|---|---|
| Displacement | 0.13 L |
| Aspiration | naturally_aspirated |
| Rated speed | 3600 rpm |
Common questions
What size generator is the Cummins/Onan K1400?
The Cummins/Onan K1400 is rated 1 kW standby (1.2 kVA).
What engine is in the Cummins/Onan K1400?
The Cummins/Onan K1400 is powered by the Cummins/Onan GS130-1-DG-A3 engine.
What kind of fuel does the Cummins/Onan K1400 run on?
The Cummins/Onan K1400 runs on regular-grade gasoline.
What's the oil capacity on a Cummins/Onan K1400?
The Cummins/Onan GS130-1-DG-A3 engine in the Cummins/Onan K1400 has an oil capacity of 0.55 liters.
Troubleshooting
6Symptoms & remedies
| Symptom | Cause | Remedy |
|---|---|---|
| Crankcase pressure might blow out hot oil and cause serious burns. | Do not attempt to check oil while the generator set is running. Add oil until it reaches the top of the oil port. | |
| Fuel level indicator looks damaged or loose. | Install a new indicator before starting generator set. | |
| Generator set operates on a slight grade, and the fuel tank is completely filled. | Do not fill completely if the generator set will operate on a slight grade. | |
| Faulty electrical equipment connected to the generator presents an electrical shock hazard. | Check all electrical equipment for frayed cords or breaks in the insulation before using. Properly applied and maintained ground fault circuit interrupters can afford additional protection against the hazard of electrical shock. | |
| Pilot lamp does not light and output voltage is OV | Faulty contact of receptacles or disconnected wiring inside of control box | Repair or replace |
| Output voltage is not delivered | Disconnected wiring | Repair or replace stator coil, demagnetization of permanent magnet, clean brush contact and slip ring, repair or replace brush, or repair or replace sub coil |
Fault codes and symptom→remedy steps extracted from this model’s service/owner documentation; verify against the official manual before servicing. Full Cummins/Onan K1400 troubleshooting guide (12 entries) →
Repair guides
10- | Trouble Checking method asurement / Possible cause Countermeasures
- @ Disconnected wiring (rear Check wiring. Repair.
- Tester is in R x 1 range.
- $s _ does not | ' wiring). Replace cir- |
- 4.1 Disassembly and reassembly of generator parts
- | Trouble Checking method asurement / Possible cause Countermeasures: *Check for short to ground condition. Test meter set on
- *Check for short to ground condition. Test meter set on
- Tester is in R x 1 range.: Tester probe (+) | Tester probe (—) tester
- Tester probe (+) | Tester probe (—) tester
- Trouble Checking method easu e u Possible cause Countermeasures: *Check for short to ground condition. Test meter set on
Step-by-step procedures compiled from the Cummins/Onan service manual for this model.
Parts
2| Part # | Description | Qty | System | |
|---|---|---|---|---|
| 981-0123 | Recoil Starter Control Panel | 1 | Recoil starter | Amazon eBay |
| M-1534 | Air Cleaner | 1 | Air cleaner | Amazon eBay |
Service, wear & replacement parts referenced for this model and its engine — confirm the exact part for your serial number. See the full parts catalog to search and cross-reference.