Specifications
| Fuel | Natural Gas / LP Vapor / LP Liquid |
|---|---|
| Frequency | 60.0 Hz |
| Standby power | 10 kW |
| Controller | Onan PCB (A11) |
| Oil capacity | 3.3 L |
| Alternator | YVB |
| Voltage options | 120/240 V |
| Circuit breaker | 50 A |
| Battery group | 26 (BCI GP 26) |
| Battery cranking | 530 CCA |
| Battery voltage | 12 V |
| Starting system | 12 V DC |
| Dimensions (L×W×H) | 1143×864×986 mm |
| Dry weight | 272 kg |
| Sound level | 70.0 dBA @ 7 m |
Engine
| Oil capacity | 3.3 L |
|---|---|
| Displacement | 0.98 L |
| Aspiration | Naturally Aspirated |
| Rated speed | 3600 rpm |
Maintenance & consumables
for the Cummins/Onan Performer P224| Item | Spec | Capacity | Part # | Interval | |
|---|---|---|---|---|---|
| Air filter | Replace Engine Air Filter | — | 500 hr | ||
| Fuel filter | — | ||||
| Oil filter | Change the engine oil and oil filter. Also, change the air filter if it is dirty. | — | 100 hr | ||
| Battery | BCI Group 26 | — | 100 hr | ||
| Belt | — | ||||
| Coolant filter | — | ||||
| Oil | 3.5 quart (3.3 liter) | 3.5 | — | 100 hr | |
| Spark plug | The genset has two spark plugs: one on each side of the engine, see Figure 3-3. | — | 500 hr |
Common questions
How many kW is the Cummins/Onan GHA?
The Cummins/Onan GHA is rated 10 kW standby.
Which engine powers the Cummins/Onan GHA?
The Cummins/Onan GHA is powered by the Cummins/Onan Performer P224 engine.
What kind of fuel does the Cummins/Onan GHA run on?
The Cummins/Onan GHA runs on Natural Gas / LP Vapor / LP Liquid.
What's the oil capacity on a Cummins/Onan GHA?
The Cummins/Onan Performer P224 engine in the Cummins/Onan GHA has an oil capacity of 3.3 liters.
How loud is the Cummins/Onan GHA?
The Cummins/Onan GHA is rated at 70.0 dBA at 7 m, per the manufacturer specification sheet.
How much does the Cummins/Onan GHA weigh?
The Cummins/Onan GHA has a dry weight of 272 kg (599 lb).
What voltage does the Cummins/Onan GHA produce?
The Cummins/Onan GHA is offered in 120/240 V.
What battery does the Cummins/Onan GHA use?
The Cummins/Onan GHA uses 12 V each, 530 CCA, group 26 (BCI GP 26), per the manufacturer specification sheet. The starting system is 12 V DC.
Which alternator is fitted to the Cummins/Onan GHA?
The Cummins/Onan GHA uses a YVB alternator.
Troubleshooting
6Symptoms & remedies
| Symptom | Remedy |
|---|---|
| Engine Cranks But Will Not Start | - Check Battery condition - Perform checks in step 01 - Check Fuel supply - Perform checks in step 01 - Check Ignition spark - Perform checks in step 01 - Check Spark plug - Perform checks in step 01 - Check Fuel pressure at carburetor - Perform checks in step 01 - Check Carbueretor piston for free movement - Perform checks in step 01 - Check Governor linkage - Perform checks in step 01 - Check Carburetor adjustments |
| Engine Oil Leak | - Clean contaminated area - Run engine and check for leaks - Add dye to oil and check for leaks |
| Engine Overfueling (Genset) | - Check Spark plug - Perform checks in step 01 - Check Fuel pressure at carburetor - Perform checks in step 01 - Check Carbueretor piston for free movement - Perform checks in step 01 - Check Governor linkage - Perform checks in step 01 - Check Carburetor adjustments |
| Engine Starts But Stops When Switch is Released | - Check Fuel pressure - Perform checks in step 01 - Check AC output when running - Perform checks in step 01 - Check Quadrature voltage - Perform checks in step 01 - Check Remote start/stop switch - Perform checks in step 01 - Check ATS input control - Evaluate fault codes, if present |
| Engine Unstable (Hunts) (Genset) | - Check Fuel supply - Perform checks in step 01 - Check Fuel lines for leakage - Perform checks in step 01 - Check Loose wiring connections - Perform checks in step 01 - Check Governor linkage for binding - Perform checks in step 01 - Check Governor adjustments - Perform checks in step 01 - Check Carburetor piston for free movement |
| Engine Will Not Crank | - Check Battery condition - Perform checks in step 01 - Check Battery connections - loose or dirty - Perform checks in step 01 - Check Battery cable size - Perform checks in step 01 - Evaluate fault codes - Perform checks in step 01 - Check Starter - Perform checks in step 01 - Check Start/Stop switch - Perform checks in step 01 - Check Remote connections - Perform checks in step 01 - Check Start solenoid - Perform checks in step 01 - Control - Perform checks in step 01 |
Fault codes and symptom→remedy steps extracted from this model’s service/owner documentation; verify against the official manual before servicing. Full Cummins/Onan GHA troubleshooting guide (23 entries) →
Fuel consumption
| Rating | Load | L/h | gal/h |
|---|---|---|---|
| Standby | 3.6 | 0.96 | |
| Standby | 50% | 4.4 | 1.18 |
| Standby | 100% | 9.1 | 2.41 |
Available documents