HomeCummins/OnanCummins/Onan DEH Series

Cummins/Onan DEH Series Generator Set

The Cummins/Onan DEH Series is a 30 kW (37.5 kVA) Diesel standby generator set powered by a Ford DSD 442 engine. It is available at 110/220 V, 115/230 V, 120/240 V, 120/208 V, 220/380 V, 230/400 V, 240/416 V, 254/440 V, 277/480 V and 347/600 V, 1-phase, 60 Hz and rated 156 A. It holds about 9 L (2.4 gal) of oil and 15 L (4.0 gal) of coolant. Starting uses 2 group-2 batteries at 12 V. The set measures 1680×840×1160 mm (66.1×33.1×45.7 in) and weighs about 771.1 kg (1700 lb).

30 kW
Standby
4.16 L
Displacement
9.0 L
Oil capacity
1
Document types

How to read your Cummins/Onan serial & model number →

Compare with other 30–35 kW Diesel generators →

Specifications

FuelDiesel
Frequency60.0 Hz
Standby power30 kW
Standby kVA37
Prime power25 kW
ControllerFord-Dorset
Oil capacity9.0 L
AlternatorCummins/Onan UR
Voltage options110/220 V, 115/230 V, 120/240 V, 120/208 V, 220/380 V, 230/400 V, 240/416 V, 254/440 V, 277/480 V, 347/600 V
Phase1
Rated current156 A
Power factor0.8
Battery group2H
Battery voltage12 V
Battery quantity2
Coolant capacity15.0 L
Dimensions (L×W×H)1680×840×1160 mm
Dry weight771 kg

Engine

Ford DSD 442
Oil capacity9.0 L
Coolant capacity15.0 L
Displacement4.16 L
AspirationNatural
Rated speed1800 rpm

Common questions

What is the power rating of the Cummins/Onan DEH Series?

The Cummins/Onan DEH Series is rated 30 kW standby (37.5 kVA).

What engine does the Cummins/Onan DEH Series use?

The Cummins/Onan DEH Series is powered by the Ford DSD 442 engine.

What fuel does the Cummins/Onan DEH Series use?

The Cummins/Onan DEH Series runs on Diesel.

What is the oil capacity of the Cummins/Onan DEH Series?

The Ford DSD 442 engine in the Cummins/Onan DEH Series has an oil capacity of 9.0 liters.

What alternator does the Cummins/Onan DEH Series use?

The Cummins/Onan DEH Series uses a Cummins/Onan UR alternator.

Troubleshooting

13

Fault codes

CodeMeaningRemedy
*Low oil pressure shutdown*Low oil pressure shutdown.Check— a. Oil level. Replenish if necessary: b. Sensor. Faulty sensor will shut down engine. c. Refer to engine service manual for troubleshooting guide for oil system.
*High engine temperature shutdown*High engine temperature shutdown.Check— a. Coolant level. Replenish if necessary. b. City water cooled sets. Check water flow, valves, etc. c. Check sensor; check thermostat. d. Radiator model, check fan belts, radiator for obstructions, etc.
Overspeed shutdownOverspeed shutdown.Check governor and throttle linkages, for freedom of movement. Check overspeed switch.
Overspeed light on, no shutdownOverspeed light on, no shutdown.Disconnect wire at TB11-29. Lighten after reset; replace engine monitor board.
*Low oil pressure light ON*Low oil pressure light ON. No shutdown.Disconnect wire at TB11-30. Light ON after relay reset. Replace engine monitor board.
*High engine temperature light ON*High engine temperature light ON. No shutdown.Disconnect wire at TB11-31. Light ON after relay reset. Replace engine monitor board.

Symptoms & remedies

SymptomRemedy
Engine stops cranking and fault lamp lights, after cranking approximately 75 seconds.See engine service manual for troubleshooting fuel system. After correcting problem, reset engine monitor relay by placing Run-Stop/Reset-Remote switch to Stop/Reset, then back to the required running position.
Fault lamp lights immediately after engine starts.Check for: Overspeed condition as engine starts.
Fault lamp lights and engine shuts down after running for a period.Check the following: a. Oil level. Engine will shut down if sensor is closed. b. Check engine manual for troubleshooting oil system. c. High engine temperature. Check coolant level; check water flow (city water cooled systems); check radiator for free air flow, and fan belts for tightness. See engine manual for troubleshooting cooling system. d. Check for faulty oil pressure sensor or faulty high engine temperature sensor.
Engine runs, shuts down and cranks for 75 seconds. Cranking cycle stops; fault lamp lights.Check fuel supply.
Fault lamp lights, no fault exists.To check a no-fault condition, disconnect leads from TB11 terminals 29, 30 and 31. If fault lamp lights with leads disconnected, replace engine monitor board. Reconne
Overcrank fault lamp lights and engine stops cranking after approximately 75 seconds.See engine service manual for troubleshooting fuel system. After correcting fault, reset engine monitor relay by placing Run-Stop/Reset-Remote switch to Stop/Reset position, depressing Reset button, then to the required running position.
Engine runs, shuts down, cranks for 75 seconds, cranking cycle stops, overcrank light ON.Check fuel supply.

Fault codes and symptom→remedy steps extracted from this model’s service/owner documentation; verify against the official manual before servicing.

Fuel consumption

RatingLoadL/hgal/h
Standby100%2.732.6

Available documents

Owner's manual — 976-0120 Onan DEH Operator's Manual (4-1980) (Cummins/Onan)