Service parts for the 7.0 HGJAD
Grouped by system, with how many of each the parts manual calls for.
Fuel system
1 requiredOil system
1 requiredIgnition
1 requiredPrices captured from merchant listings; some links are affiliate links. Confirm against your serial number before ordering.
Specifications
| Fuel | gasoline |
|---|---|
| Frequency | 60.0 Hz |
| Controller | A1 |
| Oil capacity | 1.8 L |
| Voltage options | 120 V, 240 V |
| Phase | 1 |
| Rated current | 29.2 (1-Ph, 4-Wire 120/240 V); 58.3 (1-Ph, 2-Wire 120 V); 16.8 (3-Ph 120/240 V) A |
| Power factor | 1.0 |
| Battery cranking | 450 CCA |
| Battery voltage | 12 volts V |
| Dry weight | 132 kg |
| Wet weight | 290 kg |
| Sound level | 66.0 dBA @ 3 m |
Filters & service parts
model family| Item | Spec | Capacity | Part # | Interval | |
|---|---|---|---|---|---|
| Air filter | Refer to Table 3 for scheduled air filter element replacement. In dusty environments the filter element should be inspected and changed more frequently. | 0140-3116 | 2 hr | Amazon eBay $9.95 | |
| Fuel filter | 0147-0860 | 500 hr | Amazon eBay $16.99 | ||
| Oil filter | WARNING: State and federal agencies have determined that contact with used engine oil can cause cancer or reproductive toxicity. Try to avoid skin contact and breathing of vapors. Use rubber gloves and wash exposed skin. | 0122-0836 | 450 hr | Amazon $11.99 eBay $10.59 | |
| Battery | WARNING: Arcing at battery terminals or light switch or other equipment or flames and sparks can ignite battery gas causing severe personal injury—Ventilate battery area before working on or near battery—Do not smoke—Switch trouble light ON / OFF away from battery—Do not disconnect battery cables while genset is running or vehicle battery charging system is on—Always disconnect negative (-) cable first and reconnect it last. | — | 1 hr | ||
| Belt | — | ||||
| Coolant | — | 5 hr | |||
| Oil | Park the vehicle on level ground and shut off the genset before checking the engine oil level. WARNING: Crankcase pressure can blow hot engine oil out the fill opening causing severe burns. Always stop the genset before removing the oil fill cap. | — | 150 hr | ||
| Spark plug | Refer to Table 3 for scheduled spark plug replacement. (The genset has two spark plugs, Figure 12.) The spark plugs must be in good condition for proper engine starting and performance. A spark plug that fouls frequently or has heavy soot deposits indicates the need for engine service. See Troubleshooting (Page Chapter 5). | 0167-1638 | 5 hr | Amazon eBay $11.95 |
Compiled from this model's family documentation — may include parts for closely-related variants. Confirm the exact part for your serial number.
Service intervals
13| Item | Action | Hours | Months | Notes |
|---|---|---|---|---|
| Engine Oil Level | Check | 8 hr | Every day or every 8 hours | |
| General Inspections | Inspect | 8 hr | Every day or every 8 hours | |
| Spark arrester | Clean | 50 hr | Every 50 hours | |
| Air Filter Element | Replace | 450 hr | more often in dusty environments | |
| Engine Oil & Oil Filter | Change | 150 hr | First service — at least once a year, more often dusty/hot | |
| Spark Arrestor | Clean | 150 hr | ||
| Cylinder Heads | Clean | 500 hr | Clean or replace; must be performed by a trained and experienced mechanic | |
| Cylinder Heads | Other | 450 hr | clean or replace; qualified mechanic | |
| Engine Cooling Fins | Clean | 450 hr | more often in dusty environments | |
| Fuel Filter | Replace | 500 hr | 36 mo | qualified mechanic; sooner if performance deteriorates |
| Spark Plugs | Replace | 450 hr | sooner if performance deteriorates | |
| Valve Lash | Adjust | 500 hr | qualified mechanic (authorized Onan dealer) | |
| Battery | Clean | 1 mo | Every Month; more often in hot weather |
Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.
Service specifications
60| Type | Item | Value | Unit | Condition |
|---|---|---|---|---|
| Clearance | Crankshaft end play | 0.005 – 0.012 | in (0.127 – 0.305 mm) | |
| Clearance | Cylinder head flatness maximum | 0.004 | in (0.1 mm) | |
| Clearance | Exhaust Valve Lash (Cold) | 0.10 | mm (0.004 in) | cold |
| Clearance | Intake Valve Lash (Cold) | 0.10 | mm (0.004 in) | cold |
| Clearance | Valve guide inside diameter standard | 0.2376 – 0.2383 | in (6.035 – 6.053 mm) | |
| Gap | Magneto Air Gap | 0.012 | in (0.3 mm) | |
| Gap | Magneto Air Gap | 0.3 | mm (0.012 in) | |
| Gap | Spark Plug Gap | 0.025 | in (0.6-0.7 mm) | |
| Gap | Spark Plug Gap | 6-7 | mm (0.025 in) | |
| Injection timing | Ignition Timing | 20 | ° BTDC, non-adjustable magneto | |
| Other | Ignition Timing | 20° BTDC | non-adjustable | |
| Pressure | Compression | 3.9 | kgf/cm2 (55.47 lbf/in2) | @ 500 RPM |
| Pressure | Crankcase Vacuum | 7 to 10 | inches of water column | measured through a tap in the oil fill cap |
| Pressure | Cylinder Compression Test | 153-188 | psi | |
| Pressure | Fuel Pump pressure (carburetor models) | 2.5 to 4 | psi (17 to 27 kPa) | |
| Pressure | Fuel Rail Pressure (EFI) | 43.5 psi (300 kPa) nominal | psi | |
| Pressure | Hydraulic Pump Inlet Conditions | 5 | in Hg Vacuum or 20 psi Pressure max | |
| Pressure | LPG Vapor Supply Pressure | 9-13 | in (228-330 mm) WC | |
| Pressure | Low Oil Pressure Cutoff | less than 17 | psi | |
| Pressure | Max Exhaust Back Pressure (HGJAF models) | 35 | in (889 mm) WC | |
| Pressure | Nominal Engine Oil Pressure | 43 | psi | |
| Resistance | Fuel injector electrical resistance | approximately 12.5 | ohms | |
| Resistance | Ignition Coil LEFT (No. 1 Cyl) maximum | 33,000 | Ohms | |
| Resistance | Ignition Coil LEFT (No. 1 Cyl) minimum | 13,700 | Ohms | |
| Resistance | Ignition Coil RIGHT (No. 2 Cyl) maximum | 27,000 | Ohms | |
| Resistance | Ignition Coil RIGHT (No. 2 Cyl) minimum | 11,500 | Ohms | |
| Resistance | MAT sensor resistance | 2600 to 3000 | ohms | |
| Resistance | Rotor winding resistance HGJAA/B/C (5.5 kW, 80 mm stack) | 29.34 | ohms @ 77° F (25° C) ± 10% | |
| Resistance | Rotor winding resistance HGJAA/B/C (6.5-7.0 kW, 95 mm stack) | 31.97 | ohms @ 77° F (25° C) ± 10% | |
| Resistance | Rotor winding resistance HGJAD/E/F | 31.97 | ohms @ 77° F (25° C) ± 10% | |
| Resistance | Stator T1-T2/T3-T4 HGJAA/B/C (5.5 kW) | 0.33 | ohms @ 77° F (25° C) ± 10% | |
| Resistance | Stator T1-T2/T3-T4 HGJAA/B/C (6.5-7.0 kW) | 0.30 | ohms @ 77° F (25° C) ± 10% | |
| Speed | Engine Speed (5.5/6.5 kW models) | 2400 | rpm | |
| Speed | Engine Speed (7.0 kW models) | 2880 | rpm | |
| Speed | Generator Speed | 3600 | rpm | |
| Speed | Idle (throttle) stop screw setting on 50 Hz genset | 41 to 43 | Hz | |
| Speed | Idle (throttle) stop screw setting on 60 Hz genset | 51 to 53 | Hz | |
| Speed | Low cranking speed shutdown threshold | 180 | rpm for more than 2 seconds | |
| Speed | Low cranking speed threshold | 180 | RPM | for more than 2 seconds triggers Code 32 |
| Speed | Overspeed shutdown threshold | 3400 | rpm | |
| Speed | Overspeed threshold (symptom-based) | 3400 | RPM | engine speed greater than triggers Code 31 |
| Speed | Rated speed | 3600 | RPM | |
| Speed | Starter disconnects / status light solid | greater than 1300 | rpm | |
| Temperature | Exhaust Gas Temperature Shutdown | 650 | °C (1202°F) | for 2 seconds triggers Code 58 |
| Torque | Belt Tensioner Center Bolt | 20 | lb-ft | |
| Torque | Belt Tensioner Center Bolt | 26 | N-m | |
| Torque | Connecting Rod Cap Bolts | 16.3-19.9 | lb-ft | |
| Torque | Crankcase Cover Screws | 16.2-16.9 | lb-ft | |
| Torque | Cylinder Head Bolts (Step 1) | 7.2 | lb-ft | |
| Torque | Cylinder Head Bolts (Step 2) | 14.5 | lb-ft | |
| Torque | Cylinder Head Bolts (Three equal increments) | 24.6-30.4 | lb-ft | |
| Torque | Cylinder Shroud Screws | 8 | lb-ft | |
| Torque | Engine Breather Valve Cover Screws | 3 | lb-ft | |
| Torque | Engine Mounting Screws | 20 | lb-ft | |
| Torque | Exhaust Manifold Flange Nuts | 20 | lb-ft | |
| Torque | Exhaust Manifold Flange Nuts | 26 | N-m | |
| Torque | Fan Screws | 11 | N-m | |
| Torque | Fan Screws | 8 | lb-ft | |
| Torque | Fan Shroud Screws | 11 | N-m | |
| Torque | Fan Shroud Screws | 8 | lb-ft |
Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.
Recommended fluids
| Fluid | Grade | Standard | Ambient | Capacity | Notes |
|---|---|---|---|---|---|
| Engine oil | API Class SJ, SH or SG | 2.0 quart (1.8 l) | Oil capacity | ||
| Engine oil | 5W-30 | API SJ, SH or SG (may combine with CH-4, CG-4 or CF-4) | -28°C to 10°C | –20° F to 50° F (–28° C to 10° C) | |
| Engine oil | 10W-30 | API SJ, SH or SG (may combine with CH-4, CG-4 or CF-4) | -18°C to 27°C | 0° F to 80° F (–18° C to 27° C) | |
| Engine oil | 10W-40 | API SJ, SH or SG (may combine with CH-4, CG-4 or CF-4) | -18°C to 27°C | 0° F to 80° F (–18° C to 27° C) | |
| Engine oil | 15W-40 (OnaMax) | API SJ, SH or SG (may combine with CH-4, CG-4 or CF-4) | -12°C to 38°C | 10° F to 100° F (–12° C to 38° C) | |
| Engine oil | 30 | above 0°C | 1.8 liters (2.0 qt) | 0°C (32°F) and higher | |
| Engine oil | SAE 30 | API SJ, SH or SG (may combine with CH-4, CG-4 or CF-4) | above 0°C | 32° F (0° C) and higher; single-grade SAE 30 preferable when temperatures consistently above freezing | |
| Engine oil | 10W-30 / 10W-40 | API SJ/SH/SG | 18°C to 27°C | 2.0 | 0F to 80F |
| Fuel | Clean, fresh unleaded gasoline, min 87 octane (Anti-Knock Index) | Do not use methanol additives; avoid leaded gasoline | |||
| Fuel | HD-5 LPG, min 90% propane | Commercial LPG may contain up to 2.5% butane | |||
| Fuel | HD-5 grade LPG (at least 90 percent propane) | Commercial LPG may contain more than 2.5 percent butane causing poor vaporization/starting below 32° F (0° C) | |||
| Fuel | HD-5 grade LPG (min 90% propane) | Commercial LPG >2.5% butane can cause poor vaporization below 32F (0C) | |||
| Fuel | Unleaded gasoline, min 87 octane | Not more than 10% ethanol; not more than 5% methanol | |||
| Fuel | Unleaded gasoline, minimum octane rating (Anti-Knock Index) 87 | Do not use gasoline/additives containing methanol; avoid leaded gasoline | |||
| Hydraulic oil | Transmission or Petroleum-Based Hydraulic Fluid | Operating Viscosity: 80-1000 SSU; Maximum Start-Up Viscosity: 4000 SSU |
Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.
Fault codes
34| Code | Name | Meaning | Severity | Action |
|---|---|---|---|---|
| 12 | Overvoltage Shutdown | Controller unable to maintain rated voltage | Shutdown | Verify FC 12; measure AC voltage and frequency; cycle loads; reduce Inverter/Charger rate; balance loads; measure winding resistance and check brush alignment per PSB-682a. |
| 13 | Undervoltage Shutdown | Controller unable to maintain rated voltage | Shutdown | Verify FC 13; measure AC voltage in/out of sense transformer; measure frequency; cycle loads; check charge rate; balance loads; measure winding resistance and check brush alignment per PSB-682a. |
| 14 | Overfrequency Shutdown | Frequency greater than 70Hz (instantaneous); greater than 66Hz but less than 70Hz for 3 continuous seconds (delayed). | Shutdown | Verify FC 14; measure AC current with vehicle loads; reduce charge rate; measure load capability; measure frequency/droop; inspect P1 pins; check air filter/exhaust; check governor, ignition and fuel system. |
| 15 | Underfrequency Shutdown | Engine governor unable to maintain rated frequency. | Shutdown | Verify FC 15; measure AC current; reduce charge rate; measure load capability; measure frequency/droop; inspect P1 pins; check air filter/exhaust; check governor and fuel system. |
| 17 | Fuel Pump Fault | Only active prior to 2001 – open fuel pump circuit at control. | Shutdown | Verify FC 17; verify fuel pump operation in prime mode; check fuse F1 (HGJAA,D); inspect P1 pins; measure continuity between E2 fuel pump leads; measure voltage between fuel pump E2+ and ground while priming. |
| 19 | Governor Actuator Shutdown | Shorted or open connection between governor leads after pressing start. | Shutdown | Verify FC 19; inspect P1 pins; P1-17 open to ground on EFI models; verify actuator function; measure resistance between actuator terminals; measure continuity between P1-28 and actuator lead; measure DC voltage at actuator while starting. |
| 2 | Low Oil Pressure Shutdown | Low oil pressure cutoff switch did not open. | Shutdown | Verify FC 2; measure oil level; inspect P1 pins per PSB-676; measure continuity across start/stop switch; measure continuity between ground and P1-13 (HGJAB,C) or P1-6 (HGJAA,D,E,F); measure oil pressure with mechanical gauge and repair/replace relief valve and oil pump. |
| 22 | Governor Actuator Overload Shutdown | Only active prior to 2001 – maximum governor output (PWM) for 10 continuous seconds. | Shutdown | Verify FC 22; measure AC current with vehicle loads; reduce charge rate; measure load capability; inspect P1 pins; check air filter, intake manifold and exhaust; measure fuel pump pressure/flow; check actuator and ignition. |
| 23 | Oil Pressure Switch Fault | Only active prior to 2001 – continuous open on oil pressure switch input before cranking. | Shutdown | Verify FC 23; verify harness lead connected to switch; inspect P1 pins; measure continuity to ground at switch and through harness at P1 connector; replace switch/harness as necessary. |
| 27 | Voltage Sense Shutdown | No sense voltage (0 VAC across S1-S2) for 1 continuous second after start disconnect. | Shutdown | Verify FC 27; measure AC voltage; reduce charge rate; inspect P1 pins; check air filter/exhaust; check governor, ignition and fuel system; check brush alignment. |
| 29 | High Battery Voltage Shutdown | Voltage across battery system is greater than 19 Volts. | Shutdown | Verify FC 29; measure DC voltage at battery, genset and connector P1; measure DC voltage with charger on and reduce boost charge rate; inspect P1 pins; replace controller. |
| 3 | Service Check Shutdown | Single-digit fault indicating shutdown due to a two-digit fault. | Shutdown | While LED is flashing three times, press stop once (1 second) to troubleshoot the two-digit fault code. |
| 31 | Overspeed Shutdown | Engine speed greater than 3400 rpm | Shutdown | Verify FC 31; measure frequency/droop; inspect P1 pins; check air filter/exhaust; check governor, ignition and fuel system. |
| 32 | Low Cranking Speed Shutdown | Prior to 2003: quadrature frequency less than 1.7Hz for 2 continuous seconds after pressing start. After 2003: less than 1.7Hz for 12 continuous seconds. HGJAD: less than 1.7Hz & engine RPM 0 for 12 continuous seconds. | Shutdown | Verify FC 32; measure battery voltage; verify engine rotation; inspect P1 pins; measure DC voltage at starter; check air filter/exhaust; check fuel and ignition; check governor. |
| 33 | Fault Code 33 | Single-digit fault indicating shutdown due to two-digit fault code; Fault Code 3 interpreted as a non-assigned Fault Code 33. | Shutdown | Verify that Last Fault is FC 3; while LED is flashing three times press stop once (1 second) to troubleshoot the two-digit fault code. |
| 35 | Control Card Failure Shutdown | Microprocessor EEPROM error occurred during self test. | Shutdown | Verify FC 35; replace control. |
| 36 | Genset Stopped Without Fault Condition | RPM less than 500 and sense voltage S1-S2 at 0 VAC when no other fault condition occurred. | Shutdown | Verify FC 36; verify whether AGS stopped the genset; verify engine rotation; inspect P1 pins; check air filter/exhaust; measure AC current; check fuel and ignition. |
| 37 | Invalid Set Configuration | Wrong frequency/rpm ratio | Shutdown | Verify FC 37; if alternating FC 37 and FC 47 reset magneto gap and retest; measure winding resistance and check brush alignment; check ignition and fuel system. |
| 38 | Overcurrent (Field Overload) Shutdown | Low power factor loads. | Shutdown | Verify FC 38; measure F1-F2 DC voltage; measure AC current; reduce charge rate; inspect P1 pins; measure load capability; check governor, air filter and exhaust. |
| 4 | Overcrank Shutdown | First-level shutdown code - Cranking exceeded 30 seconds without engine starting | Shutdown | Verify FC 4; check start/stop switch continuity; inspect P1 pins; verify engine rotation; measure DC voltage at starter; check air filter and exhaust; check fuel supply (gasoline/LPG/EFI); check governor and ignition. |
| 41 | Generator Rotor Shutdown | Only active after 2003 – field voltage F1-F2 at 0 VDC and sense voltage S1-S2 at 0 VAC for 1 continuous second. | Shutdown | Verify FC 41; measure F1-F2 DC voltage; measure AC current; inspect P1 pins; measure load capability; check fuel, ignition and windings. |
| 42 | Processor Shutdown | ROM (programming variables) error during self test. | Shutdown | Verify FC 42; replace control. |
| 43 | Processor Shutdown | RAM (programming variables) error during self test. | Shutdown | Verify FC 43; replace control. |
| 45 | Speed Sense Shutdown | While running, quadrature frequency dropped to 0Hz for 1 continuous second. | Shutdown | Verify FC 45; verify whether AGS stopped the genset; verify engine rotation; inspect P1 pins; check air filter/exhaust; check fuel, ignition and governor; check windings. |
| 47 | Ignition Shutdown | HGJAB,C: no ignition signal at P1-15 for 1 continuous second. HGJAA: no ignition signal at P1-5 for 1 continuous second. HGJAD,E,F prior to 2004: no ignition signal at P1-5 for 1 continuous second. | Shutdown | Verify FC 47; if alternating FC 47 and FC 37 reset magneto gap and retest; test magnetos; measure winding resistance and check brush alignment; check ignition. |
| 48 | Generator Field Sense Shutdown | Controller unable to sense field voltage. | Shutdown | Verify FC 48; replace control. |
| 51 | Processor Shutdown | Processor error. | Shutdown | Verify FC 51; replace control. |
| 52 | Fuel Injector Shutdown | Open or shorted fuel injector. | Shutdown | Verify FC 52; P1-17 open to ground on EFI set; inspect injector connector; inspect P1 pins; measure continuity between P1-23 INJ1 and P1-35 INJ2; measure continuity to ground; replace injector. |
| 54 | MAT Sensor Fault | Open or short circuit in the MAT sender. | Shutdown | Verify FC 54; P1-17 open to ground on EFI set; inspect sender connector; inspect P1 pins; measure continuity between P1-25 MAT(A) and P1-20 MAT(B); measure MAT resistance and replace sender as necessary. |
| 56 | MAP Sensor Fault | Open or short circuit in the MAP sender. | Shutdown | Verify FC 56; P1-17 open to ground; verify ambient pressure greater than 50kPa; inspect sender connector; inspect P1 pins; measure continuity between P1-31 MAP(A), P1-22 MAP(B), P1-30 MAP(C); measure sender resistance; measure fuel pump pressure/flow. |
| 57 | Overprime Shutdown | Priming exceeded 3 minutes. | Shutdown | Verify FC 57; check for an object holding switch in stop position; inspect P1 pins; measure continuity change across start/stop switch between neutral and stop position; disconnect external stop device if equipped. |
| 58 | Exhaust Gas Temperature Shutdown | Exhaust gas temperature reached 650°C (1202°F) for 2 seconds when running. | Shutdown | Contact Local Dealer or Distributor. |
| 81 | Exhaust Gas Temperature Sensor Open | EGT temperature fell below 60°C (140°F) for 2 minutes when running or not above 60°C within 2 minutes of starting. | Shutdown | Contact Local Dealer or Distributor. |
| 82 | Exhaust Gas Temperature Sensor Shorted | Control reads 1000°C (1832°F) for 1 second when running or during startup. | Shutdown | Contact Local Dealer or Distributor. |
Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.
Procedures
12Adjusting Governor (Mechanical) adjustment
⚠ Voltage/frequency-sensitive equipment may be damaged by power line frequency variations; disconnect them before adjustments.
Tools: Variable load bank up to 7 kW, Frequency meter (within 0.3%), Voltmeter (within 0.5%), AC ammeter
- Warm up the genset for at least 5 minutes at 1/2 to 3/4 rated load with the choke fully open.
- Adjust frequency close to the Table 8-3 value with the speed adjusting nut.
- With the engine warm, remove all loads and adjust the idle stop screw to 51-53 Hz (60 Hz genset) or 41-43 Hz (50 Hz genset).
- Let the throttle lever go and recheck/adjust No-Load frequency to Table 8-3; bump the governor arm to check stabilization.
- Connect rated load; if droop is out of spec move the governor spring hook one or two notches and recheck.
- Confirm the governor does not hunt under the loading sequence.
Adjusting Valve Lash adjustment
Tools: Socket wrench, Feeler gauge, Torque wrench
- Adjust when the engine is at room temperature.
- Remove the spark plugs so the engine is easier to turn over.
- Use a socket wrench on the generator pulley nut to turn the engine clockwise; remove the snap-in cover.
- Remove the valve covers with rags in place to catch oil.
- Turn engine until No. 2 intake valve is at max lift; adjust No. 1 intake valve lash.
- Turn engine until No. 2 exhaust valve is at max lift; adjust No. 1 exhaust valve lash.
- Turn engine until No. 1 intake valve is at max lift; adjust No. 2 intake valve lash.
- Turn engine until No. 1 exhaust valve is at max lift; adjust No. 2 exhaust valve lash.
- Secure valve covers using new gaskets and torque cover screws to 5.5 lb-ft (8 N-m).
- Replace the spark plugs and pulley nut cover.
Resetting Governor Arm adjustment
Tools: Battery terminal puller, Torque wrench
- Loosen the governor shaft nut by turning it clockwise and remove the arm.
- Use a battery terminal puller to break the taper fit of the shaft in the arm hub.
- Reattach arm and hub making sure the pins and holes engage; thread the shaft nut on counterclockwise.
- Check free rotation of the arm and let the governor spring take up all play; linkage must push throttle against the wide open throttle stop.
- Torque the shaft nut to 8 lb-ft (11 N-m) counterclockwise.
- Push the governor arm down and check for binding or interference.
Setting Ignition Coil Air Gaps adjustment
Tools: Feeler gauge, Torque wrench
- Bar the engine until the lands on the flywheel directly face the coils.
- Place a 0.012 inch (0.03 mm) thick feeler gauge between the coil and the land.
- Hold the coil tight against the feeler gauge and land and torque the two mounting bolts to 5 lb-ft (7 N-m).
Connecting Hydraulic Hoses installation
⚠ The high pressure spray from a hydraulic line can penetrate the skin, leading to possible blood poisoning.
Tools: Two wrenches
- Provide enough slack in connected hoses to prevent strain due to pump movement.
- Support, restrain and protect hydraulic hose to prevent chaffing.
- Do not bend hose tighter than the hose manufacturer recommends.
- Use wide-sweep 90-degree fittings.
- Always use two wrenches when tightening hydraulic fittings.
- Install an SAE Class 4 filter (10 micron) in the system.
- Fill the reservoir and crank the engine with spark plug cables disconnected until oil reaches the pump.
- Purge air by running the genset a few seconds at a time until metallic noise stops.
Installing the Genset installation
- Repair any damage to and seal all holes in the vapor-tight, fire-resistive barrier between genset and coach interior.
- Make sure all mounting bolts and brackets are secure.
- Make sure all battery, AC output, control, exhaust and fuel connections are proper and in good repair.
- Perform the service checklist before placing the genset in service.
Installing the Hydraulic Pump installation
⚠ Running the genset without oil in the hydraulic pump will destroy the pump.
⚠ The high pressure spray from a leak or fitting in a hydraulic line can penetrate the skin, leading to possible blood poisoning.
Tools: Torque wrench
- Apply molybdenum disulfide paste or equivalent to the shaft spline.
- Torque the two flange screws to 20 lb-ft (26 N-m).
- Do not start the genset before the pump is connected and filled with oil.
Removing the Genset (Disconnecting) installation
⚠ Arcing at battery terminals can ignite battery gas causing severe personal injury.
⚠ Gasoline and LPG are flammable and explosive and can cause severe personal injury or death.
⚠ LPG sinks and can accumulate in explosive concentrations.
- Disconnect all battery cables (negative first) at the battery terminals.
- Disconnect the negative and positive battery cables at the genset.
- Disconnect the wiring connectors for remote control and remote fuel pump.
- Disconnect the generator AC output wires and conduit from the junction box.
- Disconnect the exhaust tail pipe.
- Gasoline models: disconnect the fuel line(s) and securely plug the ends.
- LPG models: close the fuel shutoff valve(s), move the vehicle outside and away from below-grade spaces, purge LPG, then disconnect and plug.
Changing Engine Oil and Oil Filter maintenance
⚠ Contact with used engine oil can cause cancer or reproductive toxicity.
⚠ Crankcase pressure can blow hot engine oil out the fill opening causing severe burns.
- Place a pan underneath the oil drain hose and filter; run then stop the engine when warm.
- Remove the oil fill cap, open the oil drain valve, let all oil drain, then close the drain valve.
- High Pressure LPG gensets: drain accumulated sludge by opening the sludge drain valve, then re-close.
- Spin off the old oil filter and wipe the mounting surface; remove the old gasket.
- Apply a film of oil to the filter gasket and spin the new filter on by hand until the gasket touches; then turn 1/2 to 3/4 turn.
- Refill with 2 quarts (1.8 l) of oil; check and add or drain as necessary.
- Dispose of used oil and oil filter per local environmental regulations.
Checking Engine Oil Level maintenance
⚠ Crankcase pressure can blow hot engine oil out the fill opening causing severe burns. Always stop the genset before removing the oil fill cap.
- Park the vehicle on level ground and shut off the genset.
- Unscrew the oil fill cap and wipe oil off the dipstick; screw the cap back on, remove it and check level.
- Add or drain oil as necessary; keep level between FULL and ADD marks.
- Recheck the level in a few minutes and screw the oil fill cap back on securely.
Cleaning the Spark Arrester maintenance
⚠ Hot muffler can cause severe burns
Tools: 7/16-inch 8-point socket, 3-inch extension, swivel section, 6-inch extension, 3/8-inch drive socket wrench
- Remove the cleanout plug
- Start and load generator set to near full power for about 5 minutes to expel soot
- Stop generator set, allow muffler to cool, reinstall plug
Cleaning the Spark Arrestor maintenance
⚠ A hot muffler can cause severe burns. Let the muffler cool down before removing or installing cleanout plugs or screens.
Tools: 7/16 inch eight point socket wrench
- Locate the cleanout plug by hand and seat a 7/16 inch, eight point, 3/8 inch drive socket with extension on the plug.
- Remove the plug.
- Start and load the genset to near full power and run about five minutes to expel soot.
- Stop the genset, allow the muffler to cool, then reinstall the plug.
Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.
Common questions
What kind of fuel does the Cummins/Onan 7.0 HGJAD run on?
The Cummins/Onan 7.0 HGJAD runs on gasoline.
What oil filter does the Cummins/Onan 7.0 HGJAD use?
The Cummins/Onan 7.0 HGJAD uses oil filter part number 0122-0836.
What fuel filter fits the Cummins/Onan 7.0 HGJAD?
The Cummins/Onan 7.0 HGJAD uses fuel filter part number 0147-0860.
Which air filter part number does the Cummins/Onan 7.0 HGJAD take?
The Cummins/Onan 7.0 HGJAD uses air filter part number 0140-3116.
Troubleshooting
6Fault codes
| Code | Meaning | Remedy |
|---|---|---|
| CODE NO. 12 | OVERVOLTAGE SHUTDOWN—Controller unable to maintain rated voltage | Corrective Action: See an authorized Onan dealer. |
| CODE NO. 13 | UNDERVOLTAGE SHUTDOWN—Controller unable to maintain rated voltage | Corrective Action: Reduce the number of connected appliances, especially when air conditioners and battery chargers are running. |
| CODE NO. 14 | OVERFREQUENCY SHUTDOWN—Engine governor unable to maintain rated frequency | Corrective Action: See an authorized Onan dealer. |
| CODE NO. 15 | UNDERFREQUENCY SHUTDOWN—Engine governor unable to maintain rated frequency | Corrective Action: Reduce the number of connected appliances, especially when air conditioners and battery chargers are running. |
| CODE NO. 19 | GOVERNOR ACTUATOR SHUTDOWN—Controller sensed open or shorted circuit | Corrective Action: See an authorized Onan dealer. |
| CODE NO. 22 | GOVERNOR ACTUATOR OVERLOAD SHUTDOWN—Duration of operation at or near full-duty cycle beyond design limit | Corrective Action: Reduce the number of connected appliances, especially when air conditioners and battery chargers are running. Service the air cleaner (Page Section 4.5). Check for and repair a blocked exhaust system. |
Fault codes and symptom→remedy steps extracted from this model’s service/owner documentation; verify against the official manual before servicing. Full Cummins/Onan 7.0 HGJAD troubleshooting guide (67 entries) →
Parts
4model family| Part # | Description | Qty | System | |
|---|---|---|---|---|
| 17208238 | 3.1L, 196.5g working capacity | 1 | Carbon canister | Amazon eBay |
| 983-0102 | Battery area before working on or near battery—Wear safety glasses—Do not smoke—Switch trouble light ON / OFF away from battery—Do not disconnect battery cables while genset is running or vehicle battery charging system is on—Always disconnect negative (-) cable first and reconnect it last. | Battery | Amazon eBay | |
| 0148-1343 | vent filter | 1 | Service part / kit | Amazon eBay |
| 17208252 | 3.3L, 233.8g working capacity | 1 | Service part / kit | buy |
Compiled from this model's family documentation — may include parts for closely-related variants. Confirm the exact part for your serial number. See the full parts catalog to search and cross-reference.
Fuel consumption
| Rating | Load | L/h | gal/h |
|---|---|---|---|
| 1.6 | 0.43 | ||
| 50% | 2.7 | 0.7 | |
| 100% | 4.3 | 1.13 | |
| Full load | 4.3 | 1.13 | |
| Half load | 2.7 | 0.7 | |
| No load | 1.6 | 0.43 | |
| Standby | 1.6 | 0.43 | |
| Standby | 50% | 2.7 | 0.7 |
| Standby | 100% | 4.3 | 1.13 |