| Dizziness | | GET OUT INTO THE FRESH AIR IMMEDIATELY. If symptoms persist, seek medical attention. Shut down the genset and do not operate it until it has been inspected and repaired. |
| Muscular Twitching | | GET OUT INTO THE FRESH AIR IMMEDIATELY. If symptoms persist, seek medical attention. Shut down the genset and do not operate it until it has been inspected and repaired. |
| Vomiting | | GET OUT INTO THE FRESH AIR IMMEDIATELY. If symptoms persist, seek medical attention. Shut down the genset and do not operate it until it has been inspected and repaired. |
| Weakness and Sleepiness | | GET OUT INTO THE FRESH AIR IMMEDIATELY. If symptoms persist, seek medical attention. Shut down the genset and do not operate it until it has been inspected and repaired. |
| Inability to Think Coherently | | GET OUT INTO THE FRESH AIR IMMEDIATELY. If symptoms persist, seek medical attention. Shut down the genset and do not operate it until it has been inspected and repaired. |
| Generator output connections must be made by a qualified electrician | | Make generator output connections only by a qualified electrician in accordance with applicable codes. |
| The genset must not be connected to the public utility or any other source of electrical power. | | Do not connect the genset to the public utility or any other source of electrical power. Use an approved switching device to prevent interconnections. |
| Generator sets use substances that can cause health risks | | Use appropriate personal protective equipment when exposed to fuel, oil, coolant, wet batteries, grease, cleaning agents, or other substances. Use proper containers for transport, storage, and disposal of waste substances. Follow local regulations. |
| STARTING BATTERIES RUN DOWN | (Marginal batteries, connections, or charging system or, parasitic loads) | 1. Clean and tighten the positive (+) and negative (−) battery cable connections at the battery, vehicle frame and genset. 2. Recharge or replace the battery. Refer to the battery manufacturer’s recommendations. 3. Have a battery charging system installed or serviced in the vehicle. |
| STARTER ENGAGES-DISENGAGES | (Cranking voltage dips below 6 volts—low battery charge, poor connections, long cables) | 1. Have the vehicle propulsion engine running while trying to start the genset—the battery charging alternator may be able to maintain starting voltage high enough to get the genset started. 2. Clean and tighten the positive (+) and negative (−) battery cable connections at the battery, vehicle frame and genset. 3. Recharge or replace the battery. Refer to the battery manufacturer’s recommendations. 4. Increase battery cable size or run parallel cables. |
| STATUS INDICATOR LIGHT GOES OUT WHILE CRANKING—NO START | (Internal short circuit caused automatic-reset circuit protective device to trip) | Try starting again. See an authorized Onan dealer if the status indicator light flashes and then goes out again without the engine starting. |
| NO POWER—GENSET RUNNING, STATUS LIGHT ON | (Line circuit breaker OFF, or tripped due to short circuit or overload) | 1. Turn on or reset the line circuit breaker on the genset (Page 2-3). 2. Turn on or reset the line circuit breakers on the main distribution panel in the vehicle. |
| The engine fails to crank. | | A. Try starting at the genset rather than at the remote control. b. Replace the fuse on the control panel if it has blown. c. Clean and tighten the positive (+) and negative (- ) battery cable connections at the battery and the genset. d. Recharge the battery. Refer to the battery manufacturer’s recommendations. |
| The engine cranks slowly. | | A. Disconnect the air conditioner and other large loads. b. Clean and tighten the positive (+) and negative (- ) battery cable connections at the battery and the genset. c. Recharge the battery. Refer to the battery manufacturer’s recommendations. d. Change the engine oil to oil having the proper viscosity for the ambient temperature. See Table 1. |
| The engine cranks but fails to start. | | A. Check the fuel tank and fill if necessary. b. Open any closed fuel shut off valve. c. Check engine oil level and add oil as necessary. d. Service the air cleaner. e. Secure the spark plug lead on the spark plug. f. Replace the spark plug. |
| The engine runs and then stops or surges. | | A. Check the fuel tank and fill if necessary. b. Check the engine oil level and add oil as necessary. Drain excess oil if the level is above the dipstick Full mark. c. Check and reset the carburetor altitude adjust knob. See Varying Operating Conditions. (Gasoline models only.) d. Secure the spark plug lead on the spark plug. e. Replace the spark plug. |
| The genset keeps stalling or the circuit breaker keeps tripping. | | A. Try running with fewer appliances connected. See Powering Equipment. b. Check the fuel tank (LPG models) and fill as necessary. On cold days the LPG container may have to be kept at least half full to provide the rate of vaporization necessary to keep up with the genset fuel demand. |
| There is no electrical power even though the genset runs. | | A. Reset tripped circuit breakers. See Powering Equipment. b. Unless there is an automatic power transfer switch, plug the vehicle power cord into the genset power output receptacle (if so equipped) or turn the vehicle power selector switch to its genset position (if so equipped). |
| The remote battery condition meter indicates low voltage. | | A. Clean and tighten the positive (+) and negative (- ) battery cable connections at the battery and the genset. b. Recharge the battery. Refer to the battery manufacturer’s recommendations. |
| Black smoke exits the tailpipe. | | Service the air cleaner. |